{"id":13451,"date":"2026-09-14T03:19:04","date_gmt":"2026-09-14T03:19:04","guid":{"rendered":"https:\/\/enochtec.com\/?post_type=eno_product&#038;p=13451"},"modified":"2026-11-05T02:11:28","modified_gmt":"2026-11-05T02:11:28","slug":"bezkontaktni-ocni-tonometr-st-1000p","status":"publish","type":"eno_product","link":"https:\/\/enochtec.com\/cs\/produkty\/bezkontaktni-ocni-tonometr-st-1000p\/","title":{"rendered":"Bezkontaktn\u00ed o\u010dn\u00ed tonometr ST-1000P"},"content":{"rendered":"<h2>Bezkontaktn\u00ed tonometr ST-1000P pro automatick\u00e9 m\u011b\u0159en\u00ed NOT<\/h2>\n<p>Bezkontaktn\u00ed tonometr <strong>ST-1000P<\/strong> umo\u017e\u0148uje automatick\u00e9 m\u011b\u0159en\u00ed nitroo\u010dn\u00edho tlaku pomoc\u00ed du\u00e1ln\u00edho optick\u00e9ho sn\u00edm\u00e1n\u00ed a sn\u00edm\u00e1n\u00ed tlaku vzduchu. ENOCHTEC nab\u00edz\u00ed dv\u011b souvisej\u00edc\u00ed konfigurace, ST-1000 a ST-1000P; kompenzace tlou\u0161\u0165ky rohovky je dostupn\u00e1 u modelu ST-1000P. Nakl\u00e1p\u011bc\u00ed dotykov\u00fd displej o \u00fahlop\u0159\u00ed\u010dce 10,1 palce a motoricky ovl\u00e1dan\u00e1 op\u011brka brady usnad\u0148uj\u00ed nastaven\u00ed polohy a kontrolu p\u0159i b\u011b\u017en\u00e9m o\u010dn\u00edm vy\u0161et\u0159en\u00ed.<\/p>\n<h2>Video: postup m\u011b\u0159en\u00ed tonometrem ST-1000P<\/h2>\n<figure class=\"wp-block-video\"><video style=\"width:100%;aspect-ratio:16\/9;object-fit:contain;background:#fff\" controls preload=\"none\" playsinline poster=\"https:\/\/enochtec.com\/wp-content\/uploads\/2026\/09\/st-1000p-main-enochtec-1024x768.png\" src=\"https:\/\/enochtec.com\/wp-content\/uploads\/2026\/11\/enochtec-st-1000p-tonometer-workflow-web-cs.mp4\"><\/video><figcaption>Bezkontaktn\u00ed tonometr ST-1000P: polohov\u00e1n\u00ed pacienta, ru\u010dn\u00ed a automatick\u00e9 vyrovn\u00e1n\u00ed, hodnoty NOT v mmHg a tisk v\u00fdsledk\u016f.<\/figcaption><\/figure>\n<h2>Jak funguje bezkontaktn\u00ed tonometr?<\/h2>\n<p>Bezkontaktn\u00ed tonometr m\u011b\u0159\u00ed nitroo\u010dn\u00ed tlak tak, \u017ee na rohovku vy\u0161le kr\u00e1tk\u00fd vzduchov\u00fd impulz a optick\u00fdm senzorem zachyt\u00ed okam\u017eik jej\u00edho zplo\u0161t\u011bn\u00ed; \u010d\u00edm vy\u0161\u0161\u00ed je tlak uvnit\u0159 oka, t\u00edm v\u011bt\u0161\u00ed s\u00edla vzduchu je pot\u0159eba k jeho zplo\u0161t\u011bn\u00ed. Oka se nic nedotkne, tak\u017ee nejsou pot\u0159eba \u017e\u00e1dn\u00e9 anestetick\u00e9 kapky ani jednor\u00e1zov\u00e9 sondy. ST-1000P vyu\u017e\u00edv\u00e1 tuto kombinaci sn\u00edm\u00e1n\u00ed tlaku vzduchu a dvoj\u00edho optick\u00e9ho sn\u00edm\u00e1n\u00ed s automatick\u00fdm m\u011b\u0159en\u00edm a a\u017e 10 m\u011b\u0159en\u00edmi na oko.<\/p>\n<h2>Rozsah m\u011b\u0159en\u00ed a polohov\u00e1n\u00ed<\/h2>\n<p>ST-1000P nab\u00edz\u00ed voliteln\u00e9 rozsahy NOT 1\u201330 mmHg a 1\u201360 mmHg. Pro ka\u017ed\u00e9 oko lze ulo\u017eit a\u017e 10 nam\u011b\u0159en\u00fdch hodnot, kter\u00e9 m\u016f\u017ee obsluha porovnat. Pracovn\u00ed vzd\u00e1lenost je nejm\u00e9n\u011b 11 mm.<\/p>\n<ul>\n<li><strong>Rozsah NOT:<\/strong> 1\u201330 mmHg nebo 1\u201360 mmHg.<\/li>\n<li>V\u00fdsledky m\u011b\u0159en\u00ed: a\u017e 10 m\u011b\u0159en\u00ed na oko; pro ka\u017ed\u00e9 oko lze vytisknout t\u0159i vybran\u00e9 v\u00fdsledky.<\/li>\n<li><strong>Pracovn\u00ed vzd\u00e1lenost:<\/strong> minim\u00e1ln\u011b 11 mm.<\/li>\n<li><strong>Posuv vp\u0159ed\/vzad:<\/strong> nejm\u00e9n\u011b 30 mm.<\/li>\n<li><strong>Posuv vodorovn\u011b\/svisle:<\/strong> 90 mm \/ 30 mm.<\/li>\n<li><strong>Displej:<\/strong> 10,1palcov\u00fd v\u00fdklopn\u00fd dotykov\u00fd displej.<\/li>\n<li><strong>Polohov\u00e1n\u00ed pacienta:<\/strong> motorick\u00e1 op\u011brka brady.<\/li>\n<li>Re\u017eim m\u011b\u0159en\u00ed: automatick\u00fd \/ ru\u010dn\u00ed.<\/li>\n<li>Ovl\u00e1d\u00e1n\u00ed: automatick\u00e9 rozpozn\u00e1n\u00ed a p\u0159ep\u00edn\u00e1n\u00ed lev\u00e9ho a prav\u00e9ho oka, m\u011b\u0159en\u00ed obou o\u010d\u00ed jedn\u00edm tla\u010d\u00edtkem.<\/li>\n<li>V\u00fdstup dat: USB 2.0.<\/li>\n<li>Tisk: je uveden tisk v\u00fdsledk\u016f; v nab\u00eddce potvr\u010fte, zda se p\u0159\u00edstroj dod\u00e1v\u00e1 s vestav\u011bnou tisk\u00e1rnou.<\/li>\n<li>Rozm\u011bry a hmotnost: 380 \u00d7 460 \u00d7 505 mm; 19,7 kg.<\/li>\n<\/ul>\n<h2>ST-1000, nebo ST-1000P: kterou konfiguraci zvolit?<\/h2>\n<p>ST-1000 a ST-1000P jsou varianty stejn\u00e9 \u0159ady bezkontaktn\u00edch tonometr\u016f. Oba m\u011b\u0159\u00ed nitroo\u010dn\u00ed tlak pln\u011b automaticky s kombinovan\u00fdm optick\u00fdm a vzduchov\u00fdm sn\u00edm\u00e1n\u00edm: jedn\u00edm dotykem se spust\u00ed m\u011b\u0159en\u00ed a senzor postupn\u011b vyhled\u00e1, vycentruje a zaost\u0159\u00ed ka\u017ed\u00e9 oko. K dispozici je i ru\u010dn\u00ed ovl\u00e1d\u00e1n\u00ed. Rozd\u00edl spo\u010d\u00edv\u00e1 v tom, \u017ee ST-1000P dok\u00e1\u017ee nam\u011b\u0159en\u00fd nitroo\u010dn\u00ed tlak korigovat podle centr\u00e1ln\u00ed tlou\u0161\u0165ky rohovky, kde\u017eto ST-1000 ne.<\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Polo\u017eka<\/th>\n<th scope=\"col\">ST-1000<\/th>\n<th scope=\"col\">ST-1000P<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">M\u011b\u0159en\u00ed<\/th>\n<td>Bezkontaktn\u00ed, pln\u011b automatick\u00e9, optick\u00e9 a vzduchov\u00e9 sn\u00edm\u00e1n\u00ed<\/td>\n<td>Bezkontaktn\u00ed, pln\u011b automatick\u00e9, optick\u00e9 a vzduchov\u00e9 sn\u00edm\u00e1n\u00ed<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ovl\u00e1d\u00e1n\u00ed<\/th>\n<td>Automaticky jedn\u00edm dotykem, ob\u011b o\u010di; ru\u010dn\u00ed re\u017eim k dispozici<\/td>\n<td>Automaticky jedn\u00edm dotykem, ob\u011b o\u010di; ru\u010dn\u00ed re\u017eim k dispozici<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kompenzace tlou\u0161\u0165ky rohovky<\/th>\n<td>Nen\u00ed k dispozici<\/td>\n<td>K dispozici<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">V\u00fdstup dat<\/th>\n<td>USB 2.0<\/td>\n<td>USB 2.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li><strong>Zvolte ST-1000<\/strong> pro rutinn\u00ed m\u011b\u0159en\u00ed nitroo\u010dn\u00edho tlaku a screening, nap\u0159\u00edklad v optik\u00e1ch, screeningov\u00fdch programech a b\u011b\u017en\u00fdch o\u010dn\u00edch ambulanc\u00edch, kde nejsou pot\u0159eba hodnoty korigovan\u00e9 podle tlou\u0161\u0165ky rohovky.<\/li>\n<li><strong>Zvolte ST-1000P<\/strong>, pokud hodnoty korigovan\u00e9 podle centr\u00e1ln\u00ed tlou\u0161\u0165ky rohovky dopl\u0148uj\u00ed klinick\u00fd obraz, nap\u0159\u00edklad p\u0159i sledov\u00e1n\u00ed glaukomu nebo u pacient\u016f s neobvykle tenkou \u010di silnou rohovkou, v\u010detn\u011b stavu po refrak\u010dn\u00ed chirurgii.<\/li>\n<\/ul>\n<p>Jin\u00e9 rozd\u00edly v hardwaru, softwaru nebo p\u0159\u00edslu\u0161enstv\u00ed nelze p\u0159edpokl\u00e1dat, pokud nejsou uvedeny ve schv\u00e1len\u00e9 nab\u00eddce nebo v aktu\u00e1ln\u00edm dokumentu pro dan\u00fd model.<\/p>\n<p>Kompenzace tlou\u0161\u0165ky rohovky je funkc\u00ed p\u0159\u00edstroje, nikoli diagn\u00f3zou, a nezaru\u010duje klinick\u00fd v\u00fdsledek. V\u00fdsledky m\u011b\u0159en\u00ed vy\u017eaduj\u00ed odbornou interpretaci v kontextu cel\u00e9ho vy\u0161et\u0159en\u00ed.<\/p>\n<h2>Co je kompenzace tlou\u0161\u0165ky rohovky?<\/h2>\n<p>Kompenzace tlou\u0161\u0165ky rohovky upravuje hodnotu NOT podle centr\u00e1ln\u00ed tlou\u0161\u0165ky rohovky pacienta. Hodnoty tlaku z tonometr\u016f, kter\u00e9 rohovku zplo\u0161\u0165uj\u00ed, jsou ovlivn\u011bny jej\u00ed tlou\u0161\u0165kou: tlust\u0161\u00ed rohovka m\u00e1 tendenci d\u00e1vat um\u011ble vysok\u00e9 hodnoty a ten\u010d\u00ed rohovka, nap\u0159\u00edklad po refrak\u010dn\u00ed operaci, um\u011ble n\u00edzk\u00e9. Pr\u00e1v\u011b tato funkce odli\u0161uje ST-1000P od ST-1000. Tato str\u00e1nka netvrd\u00ed, \u017ee ST-1000P s\u00e1m m\u011b\u0159\u00ed centr\u00e1ln\u00ed tlou\u0161\u0165ku rohovky; v nab\u00eddce potvr\u010fte, jak se hodnota CCT z\u00edsk\u00e1v\u00e1, nap\u0159\u00edklad zda je sou\u010d\u00e1st\u00ed pachymetrick\u00fd modul.<\/p>\n<h2>Kam se hod\u00ed ST-1000P<\/h2>\n<p>ST-1000P je vhodn\u00fd pro oftalmologick\u00e9 kliniky, optometristy, nemocnice a vy\u0161et\u0159ovny, kter\u00e9 pot\u0159ebuj\u00ed bezkontaktn\u00ed m\u011b\u0159en\u00ed NOT. V nab\u00eddce tonometr\u016f ENOCHTEC zastupuje vzduchovou metodu a je t\u0159eba jej odli\u0161ovat od <a href=\"https:\/\/enochtec.com\/cs\/produkty\/prenosny-tonometr-rt-500-pro-odrazovou-tonometrii\/\">odrazov\u00e9ho tonometru<\/a>, proto\u017ee oba typy m\u011b\u0159\u00ed odli\u0161nou metodou a maj\u00ed jin\u00e9 provozn\u00ed po\u017eadavky a spot\u0159ebn\u00ed materi\u00e1l.<\/p>\n<h2>Nab\u00eddka a instalace<\/h2>\n<p>P\u0159\u00edstroj se nap\u00e1j\u00ed 220 V \/ 50 Hz. P\u0159ed objedn\u00e1vkou ov\u011b\u0159te elektrick\u00e9 po\u017eadavky c\u00edlov\u00e9ho trhu, zvolen\u00fd model, dod\u00e1van\u00e9 p\u0159\u00edslu\u0161enstv\u00ed, uspo\u0159\u00e1d\u00e1n\u00ed vy\u0161et\u0159ovac\u00edho stolku, jazyk dokumentace, po\u017eadavky na p\u0159enos dat \u010di tisk a rozsah servisu. Polo\u017eky, kter\u00e9 nejsou v tabulce parametr\u016f, nejsou standardn\u00ed sou\u010d\u00e1st\u00ed dod\u00e1vky a \u0159\u00edd\u00ed se nab\u00eddkou.<\/p>\n<h2>\u010cast\u00e9 dotazy k ST-1000P<\/h2>\n<h3>Jak\u00fd je rozsah NOT?<\/h3>\n<p>Voliteln\u00e9 rozsahy jsou 1\u201330 mmHg a 1\u201360 mmHg.<\/p>\n<h3>Kolik m\u011b\u0159en\u00ed lze prov\u00e9st na jedno oko?<\/h3>\n<p>Na jedno oko lze prov\u00e9st a\u017e 10 m\u011b\u0159en\u00ed a pro ka\u017ed\u00e9 oko lze vytisknout t\u0159i vybran\u00e9 v\u00fdsledky. Jde o po\u010det m\u011b\u0159en\u00ed, nikoli o kapacitu pam\u011bti p\u0159\u00edstroje.<\/p>\n<h3>Co odli\u0161uje ST-1000P od ST-1000?<\/h3>\n<p>Rozli\u0161uj\u00edc\u00edm znakem je kompenzace tlou\u0161\u0165ky rohovky u ST-1000P. Jak\u00fdkoli dal\u0161\u00ed rozd\u00edl mus\u00ed potvrdit nab\u00eddka nebo aktu\u00e1ln\u00ed dokumentace modelu.<\/p>\n<h3>Je ST-1000P stejn\u00fd jako odrazov\u00fd tonometr?<\/h3>\n<p>Ne. ST-1000P je automatick\u00fd bezkontaktn\u00ed tonometr vyu\u017e\u00edvaj\u00edc\u00ed sn\u00edm\u00e1n\u00ed tlaku vzduchu. Odrazov\u00e1 tonometrie je samostatn\u00fd zp\u016fsob m\u011b\u0159en\u00ed.<\/p>\n<h3>Dot\u00fdk\u00e1 se bezkontaktn\u00ed tonometr oka?<\/h3>\n<p>Ne. M\u011b\u0159en\u00ed vyu\u017e\u00edv\u00e1 vzduchov\u00fd impulz a optick\u00fd senzor, tak\u017ee nedoch\u00e1z\u00ed ke kontaktu s rohovkou a nejsou pot\u0159eba \u017e\u00e1dn\u00e9 anestetick\u00e9 kapky ani jednor\u00e1zov\u00e9 sondy.<\/p>\n<h3>Je vzduchov\u00fd impulz bolestiv\u00fd?<\/h3>\n<p>Vzduchov\u00fd pulz je kr\u00e1tk\u00fd a pacient jej obvykle vn\u00edm\u00e1 sp\u00ed\u0161e jako m\u00edrn\u00e9 fouknut\u00ed ne\u017e bolest, n\u011bkte\u0159\u00ed pacienti v\u0161ak mrknou nebo ucuknou. U pacient\u016f, kter\u00fdm toto vy\u0161et\u0159en\u00ed \u010din\u00ed pot\u00ed\u017ee, m\u016f\u017ee l\u00e9ka\u0159 zv\u00e1\u017eit tak\u00e9 p\u0159enosn\u00fd <a href=\"https:\/\/enochtec.com\/cs\/produkty\/prenosny-tonometr-rt-500-pro-odrazovou-tonometrii\/\">odrazov\u00fd tonometr<\/a>.<\/p>\n<h3>Pro\u010d se m\u016f\u017ee bezkontaktn\u00ed m\u011b\u0159en\u00ed li\u0161it od Goldmannovy tonometrie?<\/h3>\n<p>R\u016fzn\u00e9 tonometry m\u011b\u0159\u00ed tlak r\u016fzn\u00fdmi zp\u016fsoby a nam\u011b\u0159en\u00e9 hodnoty mohou b\u00fdt ovlivn\u011bny tak\u00e9 tlou\u0161\u0165kou rohovky a faktory pacienta. L\u00e9ka\u0159 interpretuje v\u00fdsledek spolu s \u0161ir\u0161\u00edm vy\u0161et\u0159en\u00edm a rozhodne, zda je pot\u0159eba potvrzen\u00ed jinou metodou.<\/p>\n<p>Prohl\u00e9dn\u011bte si dal\u0161\u00ed <a href=\"https:\/\/enochtec.com\/cs\/produkty\/\">oftalmologick\u00e9 diagnostick\u00e9 p\u0159\u00edstroje<\/a> nebo <a href=\"https:\/\/enochtec.com\/cs\/kontakt\/\">kontaktujte ENOCHTEC<\/a> pro potvrzen\u00ed konfigurace ST-1000P pro v\u00e1\u0161 trh a pracovi\u0161t\u011b.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Automatick\u00fd bezkontaktn\u00ed tonometr ST-1000P s dvojit\u00fdm sn\u00edm\u00e1n\u00edm (optika a tlak vzduchu), voliteln\u00fdmi rozsahy NOT, kompenzac\u00ed tlou\u0161\u0165ky rohovky, 10,1palcov\u00fdm v\u00fdklopn\u00fdm dotykov\u00fdm displejem a motorickou op\u011brkou brady.<\/p>\n","protected":false},"featured_media":13452,"menu_order":0,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"product_category":[364,378],"class_list":["post-13451","eno_product","type-eno_product","status-publish","has-post-thumbnail","hentry","product_category-diagnostika-a-zobrazovani","product_category-tonometry"],"acf":{"additional_image_1":13453,"additional_image_2":"","additional_image_3":13454,"additional_image_4":13455,"additional_image_5":13456,"additional_image_6":"","additional_image_7":""},"_links":{"self":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product\/13451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product"}],"about":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/types\/eno_product"}],"version-history":[{"count":6,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product\/13451\/revisions"}],"predecessor-version":[{"id":18639,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product\/13451\/revisions\/18639"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/media\/13452"}],"wp:attachment":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/media?parent=13451"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/product_category?post=13451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}