{"id":19744,"date":"2026-11-09T13:16:27","date_gmt":"2026-11-09T13:16:27","guid":{"rendered":"https:\/\/enochtec.com\/?post_type=eno_product&#038;p=19744"},"modified":"2026-11-09T13:41:59","modified_gmt":"2026-11-09T13:41:59","slug":"md-1000ap-ultrazvukovy-biometr-pachymetr","status":"publish","type":"eno_product","link":"https:\/\/enochtec.com\/cs\/produkty\/md-1000ap-ultrazvukovy-biometr-pachymetr\/","title":{"rendered":"MD-1000A\/P Ultrazvukov\u00fd biometr A-scan a pachymetr"},"content":{"rendered":"<h2>\u0158ada MD-1000: ultrazvukov\u00fd biometr A-scan a pachymetr<\/h2>\n<p><strong>\u0158ada MD-1000 od ENOCHTEC<\/strong> je p\u0159enosn\u00fd <strong>ultrazvukov\u00fd biometr A-scan a pachymetr<\/strong> pro oftalmologii. <strong>MD-1000A<\/strong> m\u011b\u0159\u00ed axi\u00e1ln\u00ed d\u00e9lku oka a vypo\u010d\u00edt\u00e1v\u00e1 optickou mohutnost nitroo\u010dn\u00ed \u010do\u010dky (IOL), <strong>MD-1000P<\/strong> m\u011b\u0159\u00ed tlou\u0161\u0165ku rohovky a <strong>MD-1000A\/P<\/strong> spojuje ob\u011b funkce v jednom p\u0159\u00edstroji o hmotnosti 1,7 kg s dotykovou obrazovkou, no\u017en\u00edm sp\u00edna\u010dem a vestav\u011bnou termotisk\u00e1rnou.<\/p>\n<h3>Kterou verzi MD-1000 pot\u0159ebujete?<\/h3>\n<p>V\u0161echny t\u0159i modely maj\u00ed stejnou konzoli, displej, tisk\u00e1rnu i rozm\u011bry. Li\u0161\u00ed se m\u011b\u0159ic\u00edmi funkcemi a dod\u00e1van\u00fdmi sondami:<\/p>\n<table>\n<thead>\n<tr>\n<th>Funkce \/ sou\u010d\u00e1st<\/th>\n<th>MD-1000A<\/th>\n<th>MD-1000P<\/th>\n<th>MD-1000A\/P<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>Biometrie A-scan (axi\u00e1ln\u00ed d\u00e9lka, hloubka p\u0159edn\u00ed komory, tlou\u0161\u0165ka \u010do\u010dky, d\u00e9lka sklivce)<\/th>\n<td>\u2713<\/td>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>V\u00fdpo\u010det IOL (6 vzorc\u016f + 5 metod po refrak\u010dn\u00ed chirurgii)<\/th>\n<td>\u2713<\/td>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Pachymetrie rohovky<\/th>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Sonda A 10 MHz s \u010derven\u00fdm fixa\u010dn\u00edm sv\u011btlem<\/th>\n<td>\u2713<\/td>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Pachymetrick\u00e1 sonda 20 MHz<\/th>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Typick\u00e9 pou\u017eit\u00ed<\/th>\n<td>Biometrie p\u0159ed operac\u00ed katarakty<\/td>\n<td>Vy\u0161et\u0159en\u00ed p\u0159ed refrak\u010dn\u00ed chirurgi\u00ed, interpretace nitroo\u010dn\u00edho tlaku<\/td>\n<td>Ob\u011b pou\u017eit\u00ed v jednom p\u0159\u00edstroji<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Biometrie A-scan pro pl\u00e1nov\u00e1n\u00ed operace katarakty<\/h3>\n<p>Sonda A-scan 10 MHz m\u011b\u0159\u00ed hloubku p\u0159edn\u00ed komory, tlou\u0161\u0165ku \u010do\u010dky, d\u00e9lku sklivce a axi\u00e1ln\u00ed d\u00e9lku <strong>kontaktn\u00ed nebo imerzn\u00ed technikou<\/strong> (imerzn\u00ed n\u00e1stavec je voliteln\u00e9 p\u0159\u00edslu\u0161enstv\u00ed). Automatick\u00e9 m\u011b\u0159en\u00ed je k dispozici pro \u010dty\u0159i typy oka \u2013 norm\u00e1ln\u00ed, s kataraktou, afakick\u00e9 a speci\u00e1ln\u00ed \u2013 a pro obt\u00ed\u017en\u00e9 p\u0159\u00edpady slou\u017e\u00ed manu\u00e1ln\u00ed re\u017eim. Nam\u011b\u0159en\u00e9 hodnoty se seskupuj\u00ed a na obrazovce se zobrazuje pr\u016fm\u011br a sm\u011brodatn\u00e1 odchylka, tak\u017ee nekonzistentn\u00ed s\u00e9rie odhal\u00edte d\u0159\u00edv, ne\u017e v\u00fdsledek pou\u017eijete.<\/p>\n<ul>\n<li>P\u0159esnost biometrie \u00b10,05 mm, rozli\u0161en\u00ed 0,01 mm, rozsah m\u011b\u0159en\u00ed 15\u201340 mm.<\/li>\n<li>Celkov\u00e9 zes\u00edlen\u00ed 100 dB s nastaviteln\u00fdm rozsahem 0\u201350 dB a automatickou regulac\u00ed zes\u00edlen\u00ed.<\/li>\n<li>Dotykov\u00e1 obrazovka a no\u017en\u00ed sp\u00edna\u010d \u2013 m\u011b\u0159en\u00ed bez pou\u0161t\u011bn\u00ed sondy z ruky.<\/li>\n<\/ul>\n<h3>V\u00fdpo\u010det optick\u00e9 mohutnosti IOL i po refrak\u010dn\u00ed chirurgii<\/h3>\n<p>P\u0159\u00edstroj obsahuje \u0161est vzorc\u016f pro v\u00fdpo\u010det IOL: <strong>SRK-II, SRK-T, Binkhorst-II, Holladay, Hoffer-Q a Haigis<\/strong>. Pro o\u010di po refrak\u010dn\u00edch z\u00e1kroc\u00edch na rohovce je k dispozici p\u011bt speci\u00e1ln\u00edch metod: anamnestick\u00e1 metoda, double-K\/SRK-T, metoda odvozen\u00e1 z refrakce, Rosa a Shammas. Nam\u011b\u0159en\u00e1 axi\u00e1ln\u00ed d\u00e9lka se automaticky p\u0159enese do v\u00fdpo\u010dtu, dva vzorce lze porovnat vedle sebe a v\u00fdsledek se vytiskne jedn\u00edm dotykem.<\/p>\n<p>Pro v\u00fdpo\u010det IOL jsou pot\u0159eba tak\u00e9 keratometrick\u00e9 hodnoty (K), kter\u00e9 se zad\u00e1vaj\u00ed z keratometru nebo z autorefraktometru s keratometrem, nap\u0159\u00edklad <a href=\"https:\/\/enochtec.com\/cs\/produkty\/ark-8900-autorefraktometr-keratometr\/\">ARK-8900<\/a> nebo <a href=\"https:\/\/enochtec.com\/cs\/produkty\/autorefraktometr-s-keratometrem-rmk-8100\/\">RMK-8100<\/a>.<\/p>\n<h3>Ultrazvukov\u00e1 pachymetrie a korekce nitroo\u010dn\u00edho tlaku<\/h3>\n<p>Pachymetrick\u00e1 sonda 15\u201320 MHz m\u011b\u0159\u00ed tlou\u0161\u0165ku rohovky v rozsahu 230\u20131200 \u03bcm s p\u0159esnost\u00ed \u00b15 \u03bcm a rozli\u0161en\u00edm zobrazen\u00ed 1 \u03bcm. M\u011b\u0159it lze v jednom nebo ve v\u00edce bodech; opakovan\u00e1 m\u011b\u0159en\u00ed v t\u00e9m\u017ee bod\u011b se pr\u016fm\u011bruj\u00ed, co\u017e zvy\u0161uje spolehlivost. N\u011bkolik map rohovky se zobrazuje graficky.<\/p>\n<p>Tlou\u0161\u0165ka rohovky ovliv\u0148uje v\u00fdsledky aplana\u010dn\u00ed i bezkontaktn\u00ed tonometrie. MD-1000P a MD-1000A\/P maj\u00ed funkci <strong>korekce nitroo\u010dn\u00edho tlaku<\/strong>, kter\u00e1 poskytuje referen\u010dn\u00ed hodnotu podle tlou\u0161\u0165ky rohovky pro v\u00fdsledky tonometru, nap\u0159\u00edklad <a href=\"https:\/\/enochtec.com\/cs\/produkty\/bezkontaktni-ocni-tonometr-st-1000p\/\">bezkontaktn\u00edho tonometru ST-1000P<\/a> nebo <a href=\"https:\/\/enochtec.com\/cs\/produkty\/prenosny-tonometr-rt-500-pro-odrazovou-tonometrii\/\">odrazov\u00e9ho tonometru RT-500<\/a>. Klinick\u00e1 interpretace je v\u017edy na vy\u0161et\u0159uj\u00edc\u00edm l\u00e9ka\u0159i.<\/p>\n<h3>M\u00edsto MD-1000 v procesu l\u00e9\u010dby katarakty<\/h3>\n<ol>\n<li><strong>Keratometrie<\/strong> \u2013 hodnoty K z <a href=\"https:\/\/enochtec.com\/cs\/produkty\/ark-8900-autorefraktometr-keratometr\/\">autorefraktometru s keratometrem ARK-8900<\/a>.<\/li>\n<li><strong>Axi\u00e1ln\u00ed d\u00e9lka<\/strong> \u2013 biometrie A-scan p\u0159\u00edstrojem MD-1000A nebo MD-1000A\/P.<\/li>\n<li><strong>Mohutnost IOL<\/strong> \u2013 vypo\u010dten\u00e1 p\u0159\u00edmo v MD-1000 zvolen\u00fdm vzorcem a vyti\u0161t\u011bn\u00e1 do opera\u010dn\u00ed dokumentace.<\/li>\n<li><strong>Operace<\/strong> \u2013 fakoemulzifikace <a href=\"https:\/\/enochtec.com\/cs\/produkty\/md-480a-fakoemulzifikacni-system\/\">fakoemulzifika\u010dn\u00edm syst\u00e9mem MD-480A<\/a> pod <a href=\"https:\/\/enochtec.com\/cs\/produkty\/oftalmologicky-operacni-mikroskop-sm-3000l\/\">oftalmologick\u00fdm opera\u010dn\u00edm mikroskopem SM-3000L<\/a>.<\/li>\n<\/ol>\n<p>ENOCHTEC m\u016f\u017ee tato za\u0159\u00edzen\u00ed nacenit spole\u010dn\u011b pro z\u0159\u00edzen\u00ed nov\u00e9ho pracovi\u0161t\u011b kataraktov\u00e9 chirurgie. <a href=\"https:\/\/enochtec.com\/cs\/kontakt\/?model=MD-1000A%2FP%2C%20MD-480A#enquiry\">Vy\u017e\u00e1dejte si nab\u00eddku kompletn\u00edho vybaven\u00ed pro kataraktovou chirurgii<\/a>.<\/p>\n<h3>MD-1000, Enochview-1000, nebo AL-VIEW Lite?<\/h3>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>\u0158ada MD-1000<\/th>\n<th><a href=\"https:\/\/enochtec.com\/cs\/produkty\/oftalmologicky-ultrazvukovy-pristroj-pro-a-b-skenovani-enochview-1000\/\">Enochview-1000<\/a><\/th>\n<th><a href=\"https:\/\/enochtec.com\/cs\/produkty\/opticky-biometr-al-view-lite\/\">AL-VIEW Lite<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>Princip<\/th>\n<td>Ultrazvuk A-scan<\/td>\n<td>Ultrazvuk A-scan + B-scan<\/td>\n<td>Optick\u00e1 biometrie (OLCR)<\/td>\n<\/tr>\n<tr>\n<th>Kontakt s okem<\/th>\n<td>Kontaktn\u011b nebo imerzn\u011b<\/td>\n<td>Kontaktn\u011b<\/td>\n<td>Bezkontaktn\u011b<\/td>\n<\/tr>\n<tr>\n<th>Pachymetrie rohovky<\/th>\n<td>Ano (modely P a A\/P)<\/td>\n<td>Ne<\/td>\n<td>Optick\u00e9 m\u011b\u0159en\u00ed centr\u00e1ln\u00ed tlou\u0161\u0165ky rohovky<\/td>\n<\/tr>\n<tr>\n<th>Zobrazen\u00ed B-scan<\/th>\n<td>Ne<\/td>\n<td>Ano<\/td>\n<td>Ne<\/td>\n<\/tr>\n<tr>\n<th>Hust\u00e1 katarakta \/ zkalen\u00e1 m\u00e9dia<\/th>\n<td>M\u011b\u0159iteln\u00e9<\/td>\n<td>M\u011b\u0159iteln\u00e9<\/td>\n<td>Nemus\u00ed b\u00fdt m\u011b\u0159iteln\u00e9<\/td>\n<\/tr>\n<tr>\n<th>Proveden\u00ed<\/th>\n<td>P\u0159enosn\u00e9, 1,7 kg<\/td>\n<td>Pracovn\u00ed stanice<\/td>\n<td>Stoln\u00ed p\u0159\u00edstroj<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>MD-1000 zvolte pro samostatnou, p\u0159enosnou ultrazvukovou biometrii a pachymetrii s ni\u017e\u0161\u00ed investic\u00ed; Enochview-1000, pokud pot\u0159ebujete i zobrazen\u00ed zadn\u00edho segmentu v re\u017eimu B-scan; AL-VIEW Lite pro bezkontaktn\u00ed optickou biometrii u o\u010d\u00ed s \u010dir\u00fdmi m\u00e9dii. Mnoho kataraktov\u00fdch pracovi\u0161\u0165 m\u00e1 ultrazvukovou biometrii k dispozici vedle optick\u00e9ho biometru \u2013 pro o\u010di, kter\u00e9 optick\u00e9 p\u0159\u00edstroje nezm\u011b\u0159\u00ed.<\/p>\n<h3>Spr\u00e1va dat a tisk<\/h3>\n<p>P\u0159\u00edstroj ulo\u017e\u00ed a\u017e 180 z\u00e1znam\u016f pacient\u016f. U\u017eivatel si m\u016f\u017ee nastavit rychlosti \u0161\u00ed\u0159en\u00ed zvuku, parametry nitroo\u010dn\u00edho tlaku i obsah tisku a vestav\u011bn\u00e1 termotisk\u00e1rna vytiskne v\u00fdsledky jedn\u00edm dotykem.<\/p>\n<h3>Co si ujasnit p\u0159ed objedn\u00e1vkou<\/h3>\n<p>Ujasn\u011bte si model (A, P nebo A\/P), typ pachymetrick\u00e9 sondy (rovn\u00e1 nebo zahnut\u00e1), zda pot\u0159ebujete voliteln\u00fd imerzn\u00ed n\u00e1stavec, dod\u00e1vky pap\u00edru do tisk\u00e1rny, jazyk rozhran\u00ed, m\u00edstn\u00ed nap\u00e1jec\u00ed standard a dokumentaci po\u017eadovanou na c\u00edlov\u00e9m trhu. Souvisej\u00edc\u00ed p\u0159\u00edstroje najdete v sortimentu <a href=\"https:\/\/enochtec.com\/cs\/product-category\/diagnostika-a-zobrazovani\/ocni-ultrazvuk-a-biometrie\/\">o\u010dn\u00ed ultrazvuk a biometrie<\/a>. Kone\u010dn\u00fd rozsah dod\u00e1vky potvrd\u00ed p\u00edsemn\u00e1 nab\u00eddka.<\/p>\n<h3>Na \u010dem z\u00e1vis\u00ed cena biometru A-scan nebo pachymetru?<\/h3>\n<p>Cena z\u00e1vis\u00ed na konfiguraci \u2013 jen A-scan, jen pachymetr nebo kombinovan\u00fd model A\/P \u2013 a d\u00e1le na volb\u011b sond, imerzn\u00edm n\u00e1stavci, n\u00e1hradn\u00edch sond\u00e1ch a spot\u0159ebn\u00edm materi\u00e1lu, dokumentaci pro c\u00edlov\u00fd trh a dodac\u00edch podm\u00ednk\u00e1ch. Pokud tyto \u00fadaje uvedete v popt\u00e1vce, p\u0159iprav\u00edme p\u0159esnou a srovnatelnou nab\u00eddku.<\/p>\n<h3>\u010cast\u00e9 dotazy<\/h3>\n<h4>Jak\u00fd je rozd\u00edl mezi MD-1000A, MD-1000P a MD-1000A\/P?<\/h4>\n<p>MD-1000A je biometr A-scan s v\u00fdpo\u010dtem IOL, MD-1000P je ultrazvukov\u00fd pachymetr a MD-1000A\/P spojuje ob\u011b funkce i ob\u011b sondy v jednom p\u0159\u00edstroji.<\/p>\n<h4>Um\u00ed MD-1000 imerzn\u00ed biometrii?<\/h4>\n<p>Ano. A-scan pracuje kontaktn\u011b i imerzn\u011b; imerzn\u00ed n\u00e1stavec se dod\u00e1v\u00e1 jako voliteln\u00e9 p\u0159\u00edslu\u0161enstv\u00ed.<\/p>\n<h4>Jak\u00e9 vzorce pro v\u00fdpo\u010det IOL jsou k dispozici?<\/h4>\n<p>SRK-II, SRK-T, Binkhorst-II, Holladay, Hoffer-Q a Haigis a d\u00e1le p\u011bt metod pro o\u010di po refrak\u010dn\u00ed chirurgii: anamnestick\u00e1 metoda, double-K\/SRK-T, metoda odvozen\u00e1 z refrakce, Rosa a Shammas.<\/p>\n<h4>Pro\u010d m\u011b\u0159it tlou\u0161\u0165ku rohovky?<\/h4>\n<p>Tlou\u0161\u0165ka rohovky se hodnot\u00ed p\u0159ed refrak\u010dn\u00edmi z\u00e1kroky na rohovce a pom\u00e1h\u00e1 interpretovat tonometrii \u2013 ten\u010d\u00ed nebo siln\u011bj\u0161\u00ed rohovka m\u016f\u017ee nam\u011b\u0159en\u00fd nitroo\u010dn\u00ed tlak sn\u00ed\u017eit nebo zv\u00fd\u0161it. MD-1000P a MD-1000A\/P k tomu poskytuj\u00ed referen\u010dn\u00ed hodnotu pro korekci.<\/p>\n<h4>\u010c\u00edm se MD-1000 li\u0161\u00ed od ultrazvuku A\/B Enochview-1000?<\/h4>\n<p>MD-1000 je samostatn\u00fd p\u0159enosn\u00fd biometr A-scan a pachymetr. Enochview-1000 nav\u00edc zobrazuje sklivec a s\u00edtnici v re\u017eimu B-scan, pachymetrii v\u0161ak nem\u00e1.<\/p>\n<h4>M\u016f\u017ee MD-1000 nahradit optick\u00fd biometr?<\/h4>\n<p>Ob\u011b metody se dopl\u0148uj\u00ed. Optick\u00e1 biometrie je bezkontaktn\u00ed, ale vy\u017eaduje \u010dir\u00e1 m\u00e9dia; ultrazvukov\u00fd A-scan zm\u011b\u0159\u00ed axi\u00e1ln\u00ed d\u00e9lku i p\u0159es hustou kataraktu nebo jin\u00e1 zkalen\u00ed.<\/p>\n<h4>Jak\u00e9 nap\u00e1jen\u00ed p\u0159\u00edstroj pot\u0159ebuje?<\/h4>\n<p>100\u2013240 V AC, 50\/60 Hz, 50 VA \u2013 stejn\u00fd p\u0159\u00edstroj tedy funguje v s\u00edt\u00edch 110 V i 220 V.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0158ada MD-1000: ultrazvukov\u00fd biometr A-scan a pachymetr \u0158ada MD-1000 od ENOCHTEC je p\u0159enosn\u00fd ultrazvukov\u00fd biometr A-scan a pachymetr pro oftalmologii. MD-1000A m\u011b\u0159\u00ed axi\u00e1ln\u00ed d\u00e9lku oka a vypo\u010d\u00edt\u00e1v\u00e1 optickou mohutnost nitroo\u010dn\u00ed \u010do\u010dky (IOL), MD-1000P m\u011b\u0159\u00ed tlou\u0161\u0165ku rohovky a MD-1000A\/P spojuje ob\u011b funkce v jednom p\u0159\u00edstroji o hmotnosti 1,7 kg s dotykovou obrazovkou, no\u017en\u00edm sp\u00edna\u010dem a vestav\u011bnou &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/enochtec.com\/cs\/produkty\/md-1000ap-ultrazvukovy-biometr-pachymetr\/\"> <span class=\"screen-reader-text\">MD-1000A\/P Ultrazvukov\u00fd biometr A-scan a pachymetr<\/span> \u010c\u00edst d\u00e1le &raquo;<\/a><\/p>\n","protected":false},"featured_media":19689,"menu_order":0,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"product_category":[364,381,366],"class_list":["post-19744","eno_product","type-eno_product","status-publish","has-post-thumbnail","hentry","product_category-diagnostika-a-zobrazovani","product_category-ocni-ultrazvuk-a-biometrie","product_category-prenosne-ocni-diagnosticke-pristroje"],"acf":{"additional_image_1":19747,"additional_image_2":19748,"additional_image_3":"","additional_image_4":"","additional_image_5":"","additional_image_6":"","additional_image_7":""},"_links":{"self":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product\/19744","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product"}],"about":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/types\/eno_product"}],"version-history":[{"count":1,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product\/19744\/revisions"}],"predecessor-version":[{"id":19745,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/eno_product\/19744\/revisions\/19745"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/media\/19689"}],"wp:attachment":[{"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/media?parent=19744"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/enochtec.com\/cs\/wp-json\/wp\/v2\/product_category?post=19744"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}