{"id":8662,"date":"2026-09-14T03:19:04","date_gmt":"2026-09-14T03:19:04","guid":{"rendered":"https:\/\/enochtec.com\/?post_type=eno_product&#038;p=8662"},"modified":"2026-10-24T01:08:43","modified_gmt":"2026-10-24T01:08:43","slug":"al-view-lite-optisches-biometer","status":"publish","type":"eno_product","link":"https:\/\/enochtec.com\/de\/produkte\/al-view-lite-optisches-biometer\/","title":{"rendered":"AL-VIEW Lite optisches Biometer"},"content":{"rendered":"<h2>Optische OLCR-Biometrie mit automatisierter Messung<\/h2>\n<p>Das <strong>optische Biometer AL-VIEW Lite<\/strong> nutzt optische Low-Coherence-Reflektometrie (OLCR), um mehrere okulare Messwerte in einem Arbeitsablauf an einem Ger\u00e4t zu erfassen. Das System bietet automatische Augensuche, automatische Fokussierung, automatische Messung und automatischen Wechsel der Augenposition, um wiederholbare Bedienschritte zu unterst\u00fctzen.<\/p>\n<h2>Zehn ausgegebene okulare Parameter<\/h2>\n<p>Eine Messsitzung kann Achsl\u00e4nge (AL), zentrale Hornhautdicke (CCT), Vorderkammertiefe (ACD), Linsendicke (LT), Glask\u00f6rperdicke (VT), Hornhautbrechwert (K), Astigmatismus (AST), Wei\u00df-zu-Wei\u00df (WTW), Pupillendurchmesser (PD) und Exzentrizit\u00e4tsabstand (CWC) ausgeben. Diese Parameter sollten von geschultem augen\u00e4rztlichem Fachpersonal im Kontext der vorgesehenen Untersuchung und des geltenden Protokolls interpretiert werden.<\/p>\n<h2>Messbereiche<\/h2>\n<p>Der Messbereich der Achsl\u00e4nge betr\u00e4gt 14\u201333 mm bei einer Wiederholbarkeit von h\u00f6chstens 0,025 mm. Der Bereich des Hornhautbrechwerts betr\u00e4gt 36,21\u201350,60 D bei einer Wiederholbarkeit von h\u00f6chstens 0,13 D. Der Messbereich betr\u00e4gt f\u00fcr Wei\u00df-zu-Wei\u00df 7\u201316 mm, f\u00fcr den Pupillendurchmesser 2\u201313 mm und f\u00fcr AST 0\u00b0\u2013180\u00b0. Die Wiederholbarkeit betr\u00e4gt h\u00f6chstens 0,3 mm f\u00fcr WTW und PD sowie h\u00f6chstens 2\u00b0 f\u00fcr AST.<\/p>\n<section aria-labelledby=\"alview-workflow-title\" id=\"alview-workflow\">\n<p class=\"alview-kicker\">INTEGRIERTER ARBEITSPLATZ<\/p>\n<h2 id=\"alview-workflow-title\">Von der Messung zur Auswertung und zum Ausdruck<\/h2>\n<p class=\"alview-lead\">Vereinen Sie Messsteuerung, Datensatzpr\u00fcfung und lokalen Ausdruck in einem kompakten Arbeitsplatz.<\/p>\n<div class=\"alview-feature-grid\">\n<article>\n<p class=\"alview-card-label\">01 \/ INTEGRIERTER RECHNER<\/p>\n<h3>Die Untersuchung an einem Ger\u00e4t steuern<\/h3>\n<p>Integrierter Rechner und Touchdisplay vereinen Messsteuerung und Ergebnisanzeige im Instrument. Best\u00e4tigen Sie die gelieferte Software und Arbeitsplatzkonfiguration.<\/p>\n<\/article>\n<article>\n<p class=\"alview-card-label\">02 \/ LOKALER AUSDRUCK<\/p>\n<h3>Ergebnisse direkt am Ger\u00e4t drucken<\/h3>\n<p>Ein integrierter Thermodrucker erm\u00f6glicht den lokalen Ausdruck der Messergebnisse. Best\u00e4tigen Sie das enthaltene Berichtsformat, die Papierausstattung und die endg\u00fcltige Druckerkonfiguration.<\/p>\n<\/article>\n<article>\n<p class=\"alview-card-label\">03 \/ VERLAUFSKONTROLLE<\/p>\n<h3>Biometrische Ergebnisse im Verlauf pr\u00fcfen<\/h3>\n<p>Die biometrische Verlaufsanalyse ist mit der entsprechenden Softwarekonfiguration verf\u00fcgbar. Best\u00e4tigen Sie die unterst\u00fctzten Berichte, Datenbank- und Vergleichsfunktionen der gelieferten Version.<\/p>\n<\/article>\n<\/div>\n<\/section>\n<h2>Konfigurationsplanung<\/h2>\n<p>Das Ger\u00e4t verf\u00fcgt \u00fcber einen Anzeige-\/Bedienbildschirm; die genau mitgelieferte Bedienhardware, Software, Exportfunktionen und das Zubeh\u00f6r sollten jedoch f\u00fcr die jeweilige Bestellung best\u00e4tigt werden. Die Nennspannung betr\u00e4gt AC 220 V bei 50 Hz, die Leistungsaufnahme bis zu 220 VA. Bitte best\u00e4tigen Sie im freigegebenen Angebot die Stromkompatibilit\u00e4t im Zielland, die Installationsanforderungen sowie den Schulungs- und Serviceumfang.<\/p>\n<h2>H\u00e4ufige Fragen zum AL-VIEW Lite<\/h2>\n<h3>Welches Messprinzip nutzt das AL-VIEW Lite?<\/h3>\n<p>Das AL-VIEW Lite nutzt die optische Low-Coherence-Reflektometrie (OLCR) als Messprinzip.<\/p>\n<h3>Welche Parameter kann das System ausgeben?<\/h3>\n<p>Das System gibt AL, CCT, ACD, LT, VT, K, AST, WTW, PD und CWC aus. Verf\u00fcgbare Berichte, Datenbankfunktionen und Exportformate sollten f\u00fcr die gew\u00e4hlte Softwarekonfiguration best\u00e4tigt werden.<\/p>\n<h3>Wie gro\u00df ist der Messbereich der Achsl\u00e4nge?<\/h3>\n<p>Der Messbereich der Achsl\u00e4nge betr\u00e4gt 14\u201333 mm bei einer Wiederholbarkeit von h\u00f6chstens 0,025 mm.<\/p>\n<h3>Automatisiert das System die Messschritte?<\/h3>\n<p>Das System bietet Funktionen f\u00fcr automatische Augensuche, Fokussierung, Messung und Wechsel der Augenposition. Das Ger\u00e4t ist weiterhin f\u00fcr die Bedienung durch geschultes Fachpersonal gem\u00e4\u00df der freigegebenen Gebrauchsanweisung vorgesehen.<\/p>\n<p><a href=\"https:\/\/enochtec.com\/de\/produkte\/\">Sehen Sie sich das Sortiment ophthalmologischer Ger\u00e4te an<\/a> oder <a href=\"mailto:sales@enochtec.com\">schreiben Sie dem ENOCHTEC-Vertrieb<\/a> mit Ihrem Markt, der St\u00fcckzahl und der gew\u00fcnschten Konfiguration.<\/p>\n<style id=\"alview-manual-content-style\">#alview-workflow,#alview-operating-settings{scroll-margin-top:24px;margin:32px 0 42px;padding:34px 0 38px;border-top:1px solid #d5e3ed}#alview-workflow *,#alview-operating-settings *{box-sizing:border-box;min-width:0;overflow-wrap:break-word}#alview-workflow .alview-kicker,#alview-operating-settings .alview-kicker,#alview-workflow .alview-card-label{font-size:13px!important;line-height:1.5!important;font-weight:700;letter-spacing:.075em;color:#246fa5!important;margin:0 0 15px!important}#alview-workflow h2,#alview-operating-settings h2{font-size:36px!important;line-height:1.2!important;text-transform:none!important;color:#173f5b!important;margin:0 0 18px!important;max-width:900px}#alview-workflow .alview-lead{color:#506a7f!important;font-size:17px!important;line-height:1.7!important;max-width:790px;margin:0 0 26px!important}#alview-workflow .alview-feature-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:20px}#alview-workflow article{background:#fff;border:1px solid #d1e1ed;border-radius:16px;padding:27px 28px;min-width:0}#alview-workflow h3{font-size:24px!important;line-height:1.3!important;text-transform:none!important;color:#173f5b!important;margin:0 0 16px!important}#alview-workflow article>p:last-child{font-size:16px!important;line-height:1.75!important;color:#48657b!important;margin:0!important}#alview-workflow .alview-mode-list{margin:0!important}#alview-workflow .alview-mode-list>div{display:grid;grid-template-columns:87px minmax(0,1fr);gap:10px;margin-top:10px}#alview-workflow dt{font-size:14px!important;line-height:1.6!important;font-weight:700;color:#1c567d!important;margin:0!important}#alview-workflow dd{font-size:15px!important;line-height:1.6!important;color:#48657b!important;margin:0!important}#alview-operating-settings{border-bottom:1px solid #d5e3ed;margin-top:0;padding-top:30px}#alview-operating-settings .alview-settings-table{border:1px solid #d1e1ed;border-radius:14px;overflow:hidden;background:#fff;margin-top:25px}#alview-operating-settings table,body.postid-8662 .elementor-element-38b576eb table{width:100%;border-collapse:collapse;margin:0;table-layout:fixed;background:#fff!important}#alview-operating-settings th,#alview-operating-settings td,body.postid-8662 .elementor-element-38b576eb th,body.postid-8662 .elementor-element-38b576eb td{border:0!important;border-bottom:1px solid #dfe9f1!important;vertical-align:top;padding:17px 20px!important;font-size:16px!important;line-height:1.65!important;overflow-wrap:anywhere;opacity:1!important}#alview-operating-settings th,body.postid-8662 .elementor-element-38b576eb th{width:48%;text-align:left;background:#f3f7fa!important;color:#43617a!important;font-weight:600}#alview-operating-settings td,body.postid-8662 .elementor-element-38b576eb td{background:#fff!important;color:#214f70!important}#alview-operating-settings tr:last-child>*,body.postid-8662 .elementor-element-38b576eb tr:last-child>*{border-bottom:0!important}#alview-operating-settings .alview-setting-note,#alview-workflow .alview-review-scope{font-size:14px!important;color:#536d80!important;line-height:1.7!important;margin:20px 0 0!important}body.postid-8662 .elementor-element-38b576eb .elementor-widget-container{border-radius:14px;overflow:hidden}@media(max-width:650px){#alview-workflow,#alview-operating-settings{margin:26px 0 30px;padding:27px 0 30px}#alview-workflow h2,#alview-operating-settings h2{font-size:29px!important}#alview-workflow .alview-feature-grid{grid-template-columns:1fr;gap:16px}#alview-workflow article{padding:23px 21px}#alview-workflow h3{font-size:23px!important}#alview-workflow .alview-lead{font-size:16px!important}#alview-workflow .alview-mode-list>div{grid-template-columns:78px minmax(0,1fr);gap:8px}#alview-operating-settings th,#alview-operating-settings td,body.postid-8662 .elementor-element-38b576eb th,body.postid-8662 .elementor-element-38b576eb td{font-size:14px!important;padding:14px 13px!important}}<\/style>\n","protected":false},"excerpt":{"rendered":"<p>Optisches OLCR-Biometer AL-VIEW Lite mit automatisierter Messung und 10 ausgegebenen okularen Parametern, darunter Achsl\u00e4nge, Hornhautmesswerte, WTW und Pupillendurchmesser.<\/p>\n","protected":false},"featured_media":8663,"menu_order":0,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"product_category":[197,207],"class_list":["post-8662","eno_product","type-eno_product","status-publish","has-post-thumbnail","hentry","product_category-diagnose-und-bildgebung","product_category-optische-biometrie-und-myopiemanagement"],"acf":{"additional_image_1":8664,"additional_image_2":8665,"additional_image_3":8666,"additional_image_4":8667,"additional_image_5":"","additional_image_6":"","additional_image_7":""},"_links":{"self":[{"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/eno_product\/8662","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/eno_product"}],"about":[{"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/types\/eno_product"}],"version-history":[{"count":4,"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/eno_product\/8662\/revisions"}],"predecessor-version":[{"id":15061,"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/eno_product\/8662\/revisions\/15061"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/media\/8663"}],"wp:attachment":[{"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/media?parent=8662"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/enochtec.com\/de\/wp-json\/wp\/v2\/product_category?post=8662"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}