{"id":19708,"date":"2026-11-09T13:16:27","date_gmt":"2026-11-09T13:16:27","guid":{"rendered":"https:\/\/enochtec.com\/?post_type=eno_product&#038;p=19708"},"modified":"2026-11-09T13:33:47","modified_gmt":"2026-11-09T13:33:47","slug":"md-1000ap-biometro-ultrassonico-paquimetro","status":"publish","type":"eno_product","link":"https:\/\/enochtec.com\/pt-br\/produtos\/md-1000ap-biometro-ultrassonico-paquimetro\/","title":{"rendered":"MD-1000A\/P Bi\u00f4metro ultrass\u00f4nico A-scan e paqu\u00edmetro"},"content":{"rendered":"<h2>S\u00e9rie MD-1000: bi\u00f4metro ultrass\u00f4nico A-scan e paqu\u00edmetro<\/h2>\n<p>A <strong>s\u00e9rie MD-1000 da ENOCHTEC<\/strong> \u00e9 um <strong>bi\u00f4metro ultrass\u00f4nico A-scan e paqu\u00edmetro<\/strong> port\u00e1til para oftalmologia. O <strong>MD-1000A<\/strong> mede o comprimento axial e calcula o poder da lente intraocular (LIO), o <strong>MD-1000P<\/strong> mede a espessura corneana e o <strong>MD-1000A\/P<\/strong> re\u00fane as duas fun\u00e7\u00f5es em um \u00fanico equipamento de 1,7 kg com tela sens\u00edvel ao toque, pedal e impressora t\u00e9rmica integrada.<\/p>\n<h3>Qual configura\u00e7\u00e3o do MD-1000 voc\u00ea precisa?<\/h3>\n<p>Os tr\u00eas modelos t\u00eam o mesmo console, a mesma tela, a mesma impressora e as mesmas dimens\u00f5es. A diferen\u00e7a est\u00e1 nas fun\u00e7\u00f5es de medi\u00e7\u00e3o e nas sondas fornecidas:<\/p>\n<table>\n<thead>\n<tr>\n<th>Fun\u00e7\u00e3o \/ item<\/th>\n<th>MD-1000A<\/th>\n<th>MD-1000P<\/th>\n<th>MD-1000A\/P<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>Biometria A-scan (CA, profundidade da c\u00e2mara anterior, espessura do cristalino, comprimento v\u00edtreo)<\/th>\n<td>\u2713<\/td>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>C\u00e1lculo de LIO (6 f\u00f3rmulas + 5 m\u00e9todos p\u00f3s-cirurgia refrativa)<\/th>\n<td>\u2713<\/td>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Paquimetria corneana<\/th>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Sonda A de 10 MHz com luz de fixa\u00e7\u00e3o vermelha<\/th>\n<td>\u2713<\/td>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Sonda de paquimetria de 20 MHz<\/th>\n<td>\u2014<\/td>\n<td>\u2713<\/td>\n<td>\u2713<\/td>\n<\/tr>\n<tr>\n<th>Uso t\u00edpico<\/th>\n<td>Biometria para cirurgia de catarata<\/td>\n<td>Avalia\u00e7\u00e3o pr\u00e9-cirurgia refrativa e interpreta\u00e7\u00e3o da PIO<\/td>\n<td>Os dois fluxos de trabalho em um s\u00f3 equipamento<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Biometria A-scan para o planejamento da cirurgia de catarata<\/h3>\n<p>A sonda A-scan de 10 MHz mede a profundidade da c\u00e2mara anterior, a espessura do cristalino, o comprimento v\u00edtreo e o comprimento axial nos <strong>modos de contato ou de imers\u00e3o<\/strong> (a cuba de imers\u00e3o \u00e9 um acess\u00f3rio opcional). A medi\u00e7\u00e3o autom\u00e1tica est\u00e1 dispon\u00edvel para quatro tipos de olho \u2014 normal, catarata, af\u00e1cico e especial \u2014 e o modo manual atende os casos dif\u00edceis. As leituras s\u00e3o agrupadas com a m\u00e9dia e o desvio-padr\u00e3o exibidos na tela, o que facilita identificar medi\u00e7\u00f5es inconsistentes antes de usar o resultado.<\/p>\n<ul>\n<li>Precis\u00e3o biom\u00e9trica de \u00b10,05 mm, resolu\u00e7\u00e3o de 0,01 mm e faixa de medi\u00e7\u00e3o de 15\u201340 mm.<\/li>\n<li>Ganho total de 100 dB com ajuste de 0\u201350 dB e controle autom\u00e1tico de ganho.<\/li>\n<li>Tela sens\u00edvel ao toque e pedal para registrar a medi\u00e7\u00e3o sem soltar a sonda.<\/li>\n<\/ul>\n<h3>C\u00e1lculo do poder da LIO, inclusive em olhos operados de cirurgia refrativa<\/h3>\n<p>S\u00e3o seis f\u00f3rmulas de c\u00e1lculo de LIO integradas: <strong>SRK-II, SRK-T, Binkhorst-II, Holladay, Hoffer-Q e Haigis<\/strong>. Para olhos com cirurgia refrativa corneana pr\u00e9via, h\u00e1 cinco m\u00e9todos espec\u00edficos: hist\u00f3rico cl\u00ednico, duplo K\/SRK-T, derivado da refra\u00e7\u00e3o, Rosa e Shammas. O comprimento axial medido \u00e9 transferido automaticamente para a tela de c\u00e1lculo, duas f\u00f3rmulas podem ser comparadas lado a lado e o resultado \u00e9 impresso com um \u00fanico toque.<\/p>\n<p>O c\u00e1lculo da LIO tamb\u00e9m exige as leituras ceratom\u00e9tricas (K), inseridas a partir de um cerat\u00f4metro ou de um autorrefrator cerat\u00f4metro como o <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/ark-8900-autorrefrator-ceratometro\/\">ARK-8900<\/a> ou o <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/rmk-8100-auto-refrator-ceratometro\/\">RMK-8100<\/a>.<\/p>\n<h3>Paquimetria ultrass\u00f4nica e ajuste da PIO<\/h3>\n<p>A sonda de paquimetria de 15\u201320 MHz mede a espessura corneana de 230 a 1200 \u03bcm, com precis\u00e3o de \u00b15 \u03bcm e resolu\u00e7\u00e3o de 1 \u03bcm. A medi\u00e7\u00e3o pode ser feita em um ponto ou em v\u00e1rios pontos, e as medi\u00e7\u00f5es repetidas no mesmo ponto s\u00e3o calculadas em m\u00e9dia para maior confiabilidade. V\u00e1rios mapas corneanos s\u00e3o exibidos de forma gr\u00e1fica.<\/p>\n<p>A espessura corneana interfere nas leituras da tonometria de aplana\u00e7\u00e3o e de n\u00e3o contato. O MD-1000P e o MD-1000A\/P t\u00eam uma fun\u00e7\u00e3o de <strong>ajuste da PIO<\/strong> que fornece uma refer\u00eancia baseada na espessura corneana para os resultados do ton\u00f4metro, por exemplo do <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/st-1000p-tonometro-de-sopro\/\">ton\u00f4metro de sopro ST-1000P<\/a> ou do <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/rt-500-tonometro-de-rebote\/\">ton\u00f4metro de rebote RT-500<\/a>. A interpreta\u00e7\u00e3o cl\u00ednica \u00e9 sempre responsabilidade do profissional que realiza o exame.<\/p>\n<h3>Onde o MD-1000 entra no fluxo da catarata<\/h3>\n<ol>\n<li><strong>Ceratometria<\/strong>: leituras K obtidas com o <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/ark-8900-autorrefrator-ceratometro\/\">autorrefrator cerat\u00f4metro ARK-8900<\/a>.<\/li>\n<li><strong>Comprimento axial<\/strong>: biometria A-scan com o MD-1000A ou o MD-1000A\/P.<\/li>\n<li><strong>Poder da LIO<\/strong>: calculado no pr\u00f3prio MD-1000 com a f\u00f3rmula escolhida e impresso para o prontu\u00e1rio cir\u00fargico.<\/li>\n<li><strong>Cirurgia<\/strong>: facoemulsifica\u00e7\u00e3o com o <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/md-480a-sistema-facoemulsificacao\/\">sistema de facoemulsifica\u00e7\u00e3o MD-480A<\/a> sob um <a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/sm-3000l-microscopio-cirurgico-oftalmologico\/\">microsc\u00f3pio cir\u00fargico oftalmol\u00f3gico SM-3000L<\/a>.<\/li>\n<\/ol>\n<p>A ENOCHTEC pode or\u00e7ar esses equipamentos em conjunto para a implanta\u00e7\u00e3o de um novo servi\u00e7o de catarata. <a href=\"https:\/\/enochtec.com\/pt-br\/contato\/?model=MD-1000A%2FP%2C%20MD-480A#enquiry\">Solicite um or\u00e7amento do pacote completo para catarata<\/a>.<\/p>\n<h3>MD-1000, Enochview-1000 ou AL-VIEW Lite?<\/h3>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>S\u00e9rie MD-1000<\/th>\n<th><a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/enochview-1000-ultrassom-oftalmico-a-b\/\">Enochview-1000<\/a><\/th>\n<th><a href=\"https:\/\/enochtec.com\/pt-br\/produtos\/al-view-lite-biometro-optico\/\">AL-VIEW Lite<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>Princ\u00edpio<\/th>\n<td>Ultrassom A-scan<\/td>\n<td>Ultrassom A-scan + B-scan<\/td>\n<td>Biometria \u00f3ptica (OLCR)<\/td>\n<\/tr>\n<tr>\n<th>Contato com o olho<\/th>\n<td>Contato ou imers\u00e3o<\/td>\n<td>Contato<\/td>\n<td>Sem contato<\/td>\n<\/tr>\n<tr>\n<th>Paquimetria corneana<\/th>\n<td>Sim (modelos P e A\/P)<\/td>\n<td>N\u00e3o<\/td>\n<td>Espessura corneana central \u00f3ptica<\/td>\n<\/tr>\n<tr>\n<th>Imagem B-scan<\/th>\n<td>N\u00e3o<\/td>\n<td>Sim<\/td>\n<td>N\u00e3o<\/td>\n<\/tr>\n<tr>\n<th>Catarata densa \/ meios opacos<\/th>\n<td>Mensur\u00e1vel<\/td>\n<td>Mensur\u00e1vel<\/td>\n<td>Pode n\u00e3o ser mensur\u00e1vel<\/td>\n<\/tr>\n<tr>\n<th>Formato<\/th>\n<td>Port\u00e1til, 1,7 kg<\/td>\n<td>Esta\u00e7\u00e3o de trabalho<\/td>\n<td>Equipamento de mesa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Escolha o MD-1000 para biometria e paquimetria ultrass\u00f4nicas dedicadas e port\u00e1teis, com investimento menor; o Enochview-1000 quando tamb\u00e9m for preciso obter imagens B-scan do segmento posterior; e o AL-VIEW Lite para biometria \u00f3ptica sem contato em olhos com meios transparentes. Muitos servi\u00e7os de catarata mant\u00eam a biometria ultrass\u00f4nica ao lado de um bi\u00f4metro \u00f3ptico para os olhos que os aparelhos \u00f3pticos n\u00e3o conseguem medir.<\/p>\n<h3>Gerenciamento de dados e impress\u00e3o<\/h3>\n<p>O equipamento armazena at\u00e9 180 registros de pacientes. O usu\u00e1rio pode definir as velocidades ac\u00fasticas, os par\u00e2metros de PIO e o conte\u00fado da impress\u00e3o, e a impressora t\u00e9rmica integrada imprime os resultados com um \u00fanico toque.<\/p>\n<h3>O que confirmar antes do pedido?<\/h3>\n<p>Confirme o modelo (A, P ou A\/P), o tipo de sonda de paquimetria (reta ou angulada), a necessidade da cuba de imers\u00e3o opcional, o fornecimento de papel para a impressora, o idioma da interface, o padr\u00e3o el\u00e9trico local e a documenta\u00e7\u00e3o exigida no mercado de destino. Veja a linha de <a href=\"https:\/\/enochtec.com\/pt-br\/product-category\/diagnostico-e-imagem\/ultrassom-e-biometria-oftalmologica\/\">ultrassom e biometria oftalmol\u00f3gica<\/a> para outros equipamentos relacionados. A configura\u00e7\u00e3o final do fornecimento \u00e9 confirmada no or\u00e7amento por escrito.<\/p>\n<h3>O que define o pre\u00e7o de um bi\u00f4metro A-scan ou de um paqu\u00edmetro?<\/h3>\n<p>O pre\u00e7o depende da configura\u00e7\u00e3o \u2014 apenas A-scan, apenas paqu\u00edmetro ou o modelo combinado A\/P \u2014, al\u00e9m das op\u00e7\u00f5es de sonda, da cuba de imers\u00e3o, de sondas de reposi\u00e7\u00e3o e consum\u00edveis, da documenta\u00e7\u00e3o para o mercado de destino e das condi\u00e7\u00f5es de frete. Informar esses pontos na sua consulta permite preparar um or\u00e7amento preciso e compar\u00e1vel.<\/p>\n<h3>Perguntas frequentes<\/h3>\n<h4>Qual a diferen\u00e7a entre o MD-1000A, o MD-1000P e o MD-1000A\/P?<\/h4>\n<p>O MD-1000A \u00e9 um bi\u00f4metro A-scan com c\u00e1lculo de LIO, o MD-1000P \u00e9 um paqu\u00edmetro ultrass\u00f4nico e o MD-1000A\/P combina as duas fun\u00e7\u00f5es, com as duas sondas, em um \u00fanico equipamento.<\/p>\n<h4>O MD-1000 faz biometria por imers\u00e3o?<\/h4>\n<p>Sim. O A-scan funciona nos modos de contato e de imers\u00e3o; a cuba de imers\u00e3o \u00e9 fornecida como acess\u00f3rio opcional.<\/p>\n<h4>Quais f\u00f3rmulas de LIO est\u00e3o inclu\u00eddas?<\/h4>\n<p>SRK-II, SRK-T, Binkhorst-II, Holladay, Hoffer-Q e Haigis, al\u00e9m de cinco m\u00e9todos para olhos p\u00f3s-cirurgia refrativa: hist\u00f3rico cl\u00ednico, duplo K\/SRK-T, derivado da refra\u00e7\u00e3o, Rosa e Shammas.<\/p>\n<h4>Por que medir a espessura corneana?<\/h4>\n<p>A espessura corneana \u00e9 avaliada antes da cirurgia refrativa corneana e ajuda a interpretar a tonometria, j\u00e1 que c\u00f3rneas mais finas ou mais espessas podem fazer a PIO medida parecer mais baixa ou mais alta. O MD-1000P e o MD-1000A\/P oferecem uma refer\u00eancia para o ajuste da PIO.<\/p>\n<h4>Qual a diferen\u00e7a entre o MD-1000 e o ultrassom A\/B Enochview-1000?<\/h4>\n<p>O MD-1000 \u00e9 um bi\u00f4metro A-scan e paqu\u00edmetro dedicado e port\u00e1til. O Enochview-1000 acrescenta imagens B-scan do v\u00edtreo e da retina, mas n\u00e3o tem paquimetria.<\/p>\n<h4>O MD-1000 pode substituir um bi\u00f4metro \u00f3ptico?<\/h4>\n<p>Os dois m\u00e9todos se complementam. A biometria \u00f3ptica \u00e9 sem contato, mas exige meios transparentes; o A-scan ultrass\u00f4nico continua medindo o comprimento axial atrav\u00e9s de uma catarata densa ou de outras opacidades.<\/p>\n<h4>Qual alimenta\u00e7\u00e3o el\u00e9trica \u00e9 necess\u00e1ria?<\/h4>\n<p>CA 100\u2013240 V, 50\/60 Hz, 50 VA \u2014 o mesmo equipamento funciona em redes de 110 V e de 220 V.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>S\u00e9rie MD-1000: bi\u00f4metro ultrass\u00f4nico A-scan e paqu\u00edmetro A s\u00e9rie MD-1000 da ENOCHTEC \u00e9 um bi\u00f4metro ultrass\u00f4nico A-scan e paqu\u00edmetro port\u00e1til para oftalmologia. O MD-1000A mede o comprimento axial e calcula o poder da lente intraocular (LIO), o MD-1000P mede a espessura corneana e o MD-1000A\/P re\u00fane as duas fun\u00e7\u00f5es em um \u00fanico equipamento de 1,7 &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/enochtec.com\/pt-br\/produtos\/md-1000ap-biometro-ultrassonico-paquimetro\/\"> <span class=\"screen-reader-text\">MD-1000A\/P Bi\u00f4metro ultrass\u00f4nico A-scan e paqu\u00edmetro<\/span> Leia mais &raquo;<\/a><\/p>\n","protected":false},"featured_media":19689,"menu_order":0,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"product_category":[164,174,180],"class_list":["post-19708","eno_product","type-eno_product","status-publish","has-post-thumbnail","hentry","product_category-diagnostico-e-imagem","product_category-diagnostico-portatil","product_category-ultrassom-e-biometria-oftalmologica"],"acf":{"additional_image_1":19711,"additional_image_2":19712,"additional_image_3":"","additional_image_4":"","additional_image_5":"","additional_image_6":"","additional_image_7":""},"_links":{"self":[{"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/eno_product\/19708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/eno_product"}],"about":[{"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/types\/eno_product"}],"version-history":[{"count":1,"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/eno_product\/19708\/revisions"}],"predecessor-version":[{"id":19709,"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/eno_product\/19708\/revisions\/19709"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/media\/19689"}],"wp:attachment":[{"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/media?parent=19708"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/enochtec.com\/pt-br\/wp-json\/wp\/v2\/product_category?post=19708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}