{"id":13028,"date":"2026-09-14T03:19:04","date_gmt":"2026-09-14T03:19:04","guid":{"rendered":"https:\/\/enochtec.com\/products\/rt-500-rebound-tonometer\/"},"modified":"2026-10-24T01:42:55","modified_gmt":"2026-10-24T01:42:55","slug":"rt-500-rebound-tonometre","status":"publish","type":"eno_product","link":"https:\/\/enochtec.com\/tr\/urunler\/rt-500-rebound-tonometre\/","title":{"rendered":"RT-500 Rebound Tonometre"},"content":{"rendered":"\n<h2>Ta\u015f\u0131nabilir Rebound Tonometri<\/h2><p><strong>RT-500 rebound tonometre<\/strong>, g\u00f6z i\u00e7i bas\u0131nc\u0131n\u0131 (G\u0130B) \u00f6l\u00e7en el tipi bir cihazd\u0131r. Kompakt ve pille \u00e7al\u0131\u015fan yap\u0131s\u0131, farkl\u0131 konumlarda \u00f6l\u00e7\u00fcm\u00fc kolayla\u015ft\u0131r\u0131r. Her \u00f6l\u00e7\u00fcmde tek kullan\u0131ml\u0131k prob kullanan sistem, profesyonel g\u00f6z muayeneleri i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/p>\n<h2>Rebound Tonometre Nedir?<\/h2><p>Rebound tonometre, \u00e7ok hafif ve tek kullan\u0131ml\u0131k bir probu k\u0131sa bir an korneaya g\u00f6ndererek probun ne kadar h\u0131zl\u0131 yava\u015flay\u0131p geri sekti\u011fini kaydeder ve g\u00f6z i\u00e7i bas\u0131nc\u0131n\u0131 bu \u015fekilde \u00f6l\u00e7er: g\u00f6z bas\u0131nc\u0131 y\u00fckseldik\u00e7e prob daha h\u0131zl\u0131 yava\u015flar. Prob korneaya yaln\u0131zca bir an temas etti\u011finden, rebound \u00f6l\u00e7\u00fcm\u00fc genellikle anestezik damla kullan\u0131lmadan yap\u0131l\u0131r.<\/p>\n<h2>Rebound, Non-Kontakt ve Goldmann Tonometri<\/h2><p>Yayg\u0131n \u00fc\u00e7 tonometre tipi esas olarak g\u00f6ze nas\u0131l temas ettikleriyle ayr\u0131l\u0131r. Biyomikroskopta anestezik ve floresein damlalar\u0131yla yap\u0131lan Goldmann aplanasyon tonometrisi en yayg\u0131n klinik y\u00f6ntemdir. <a href=\"https:\/\/enochtec.com\/tr\/urunler\/st-1000p-non-kontakt-tonometre\/\">ST-1000P<\/a> gibi non-kontakt tonometreler korneay\u0131 bir hava darbesiyle d\u00fczle\u015ftirir ve g\u00f6ze hi\u00e7 temas etmez. RT-500 gibi rebound tonometreler el tipidir ve korneaya bir an temas eden tek kullan\u0131ml\u0131k prob kullan\u0131r; genellikle damla gerekmez. Bir\u00e7ok klinik birden fazla tipi bulundurur ve hastaya ve ortama g\u00f6re se\u00e7im yapar.<\/p>\n<h2>\u00d6l\u00e7\u00fcm Aral\u0131\u011f\u0131 ve Hassasiyet<\/h2><p>RT-500, 3 ile 70 mmHg aras\u0131nda \u00f6l\u00e7\u00fcm yapar. G\u0130B 3 ile 25 mmHg (dahil) aras\u0131ndayken \u00f6l\u00e7\u00fcm hassasiyeti \u00b11,5 mmHg, 25 mmHg&#8217;nin \u00fczerinde ve 70 mmHg&#8217;ye kadar ise \u00b12,5 mmHg&#8217;dir. Sonu\u00e7lar hem dikey hem yatay \u00f6l\u00e7\u00fcm y\u00f6n\u00fcnde al\u0131nabilir.<\/p>\n<h2>Prob ve Yaz\u0131c\u0131 Yap\u0131land\u0131rmas\u0131<\/h2><p>Tek kullan\u0131ml\u0131k problar \u00f6l\u00e7\u00fcm s\u00fcrecini kolayla\u015ft\u0131r\u0131r. Belirtilen yap\u0131land\u0131rma, bas\u0131l\u0131 sonu\u00e7lar i\u00e7in 100 tek kullan\u0131ml\u0131k prob ve bir kablosuz k\u0131z\u0131l\u00f6tesi termal yaz\u0131c\u0131 i\u00e7erir. Nihai prob adedi, yaz\u0131c\u0131, yaz\u0131c\u0131 k\u00e2\u011f\u0131d\u0131, ta\u015f\u0131ma \u00e7antas\u0131 ve di\u011fer aksesuarlar onayl\u0131 teklifte belirtilir.<\/p>\n<h2>Pil G\u00fcc\u00fc ve Ta\u015f\u0131ma Bilgileri<\/h2><p>Nominal gerilim, iki adet AA pil ile DC 3 V&#8217;tur. Cihaz\u0131n belirtilen net a\u011f\u0131rl\u0131\u011f\u0131 0,2 kg&#8217;d\u0131r. Br\u00fct a\u011f\u0131rl\u0131k 2,9 kg, ambalaj boyutlar\u0131 43,5 \u00d7 9,8 \u00d7 34,5 cm&#8217;dir. Bu bilgiler al\u0131c\u0131lar\u0131n g\u00fcnl\u00fck kullan\u0131m, depolama ve sevkiyat planlamas\u0131na yard\u0131mc\u0131 olur.<\/p>\n<h2>El Tipi Rebound Tonometre Ne Zaman Kullan\u0131\u015fl\u0131d\u0131r?<\/h2><p>El tipi rebound tonometre, hastan\u0131n masa\u00fcst\u00fc bir cihazda kolayca \u00f6l\u00e7\u00fclemedi\u011fi durumlarda en kullan\u0131\u015fl\u0131d\u0131r. Tipik durumlar aras\u0131nda \u00e7ocuklar, biyomikroskopa oturamayan hastalar, servislerde yatak ba\u015f\u0131 kontroller, muayene odas\u0131 d\u0131\u015f\u0131ndaki saha ve tarama \u00e7al\u0131\u015fmalar\u0131 ile hava \u00fcflemesinden rahats\u0131z olan hastalar bulunur. RT-500 hem dikey hem yatay y\u00f6nde \u00f6l\u00e7\u00fcm yapar; bu da oturan ve yatan hastalarda kolayl\u0131k sa\u011flar. Rebound tonometrinin bir hasta i\u00e7in uygun olup olmad\u0131\u011f\u0131na tedaviyi y\u00fcr\u00fcten hekim karar verir.<\/p>\n<section aria-labelledby=\"rt500-workflow-title\" id=\"rt500-workflow\"><p class=\"rt500-kicker\">\u00d6L\u00c7\u00dcMLER, KAYITLAR VE C\u0130HAZ UYARILARI<\/p><h2 id=\"rt500-workflow-title\">\u00d6l\u00e7\u00fcm s\u0131ras\u0131n\u0131 kolayca g\u00f6zden ge\u00e7irin<\/h2><p class=\"rt500-lead\">Ortalamay\u0131 inceleyin, kay\u0131tl\u0131 sonu\u00e7lara ula\u015f\u0131n ve profesyonel kullan\u0131m s\u0131ras\u0131nda cihaz uyar\u0131lar\u0131n\u0131 takip edin.<\/p><div class=\"rt500-feature-grid\"><article><p class=\"rt500-card-label\">01 \/ \u00d6L\u00c7\u00dcM ORTALAMASI<\/p><h3>\u00dc\u00e7 \u00f6l\u00e7\u00fcm ve ortalamas\u0131<\/h3><p>Cihaz, se\u00e7ilen g\u00f6z i\u00e7in \u00fc\u00e7 ge\u00e7erli \u00f6l\u00e7\u00fcmden sonra ortalamay\u0131 hesaplar ve g\u00f6sterir. Sonucu muayene ve profesyonel de\u011ferlendirme \u00e7er\u00e7evesinde yorumlay\u0131n.<\/p><\/article><article><p class=\"rt500-card-label\">02 \/ SONU\u00c7 GE\u00c7M\u0130\u015e\u0130<\/p><h3>Her iki g\u00f6z\u00fcn sonu\u00e7lar\u0131n\u0131 kaydedin ve inceleyin<\/h3><p>Se\u00e7ilen g\u00f6z\u00fcn sonu\u00e7lar\u0131n\u0131 g\u00f6zden ge\u00e7irip kaydedin; ard\u0131ndan kay\u0131tl\u0131 \u00f6l\u00e7\u00fcmler aras\u0131nda ileri veya geri ilerleyin. Yap\u0131land\u0131r\u0131lm\u0131\u015f harici k\u0131z\u0131l\u00f6tesi yaz\u0131c\u0131yla \u00e7\u0131kt\u0131 al\u0131nabilir.<\/p><\/article><article><p class=\"rt500-card-label\">03 \/ EKRAN UYARILARI<\/p><h3>Prob ve mesafe uyar\u0131lar\u0131n\u0131 takip edin<\/h3><p>Ekran mesajlar\u0131; probun bulunmamas\u0131, prob yan\u0131t\u0131n\u0131n uygun olmamas\u0131 veya konumun \u00e7ok yak\u0131n ya da uzak olmas\u0131 gibi durumlar\u0131 bildirir. Bir uyar\u0131 g\u00f6r\u00fcnd\u00fc\u011f\u00fcnde ge\u00e7erli kullan\u0131m talimatlar\u0131n\u0131 izleyin.<\/p><\/article><article><p class=\"rt500-card-label\">04 \/ P\u0130L Y\u00d6NET\u0130M\u0130<\/p><h3>Ekran \u0131\u015f\u0131\u011f\u0131 ve otomatik kapanma<\/h3><p>Ekran arka \u0131\u015f\u0131\u011f\u0131 a\u00e7\u0131l\u0131p kapat\u0131labilir. Cihaz \u00fc\u00e7 dakika kullan\u0131lmad\u0131\u011f\u0131nda otomatik olarak kapan\u0131r.<\/p><\/article><\/div><\/section><section id=\"rt500-operating-settings\"><p class=\"rt500-kicker\">EK B\u0130LG\u0130LER<\/p><h2>\u00c7al\u0131\u015fma ko\u015fullar\u0131na genel bak\u0131\u015f<\/h2><div class=\"rt500-settings-table\"><table><tbody><tr><th scope=\"row\">\u00c7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131<\/th><td>+5 ile +40 \u00b0C<\/td><\/tr><tr><th scope=\"row\">\u00c7al\u0131\u015fma ba\u011f\u0131l nemi<\/th><td>\u226480%<\/td><\/tr><tr><th scope=\"row\">\u00c7al\u0131\u015fma atmosfer bas\u0131nc\u0131<\/th><td>700\u20131060 hPa<\/td><\/tr><tr><th scope=\"row\">Nominal giri\u015f g\u00fcc\u00fc<\/th><td>1 VA<\/td><\/tr><\/tbody><\/table><\/div><p class=\"rt500-setting-note\">E\u011fitimli g\u00f6z sa\u011fl\u0131\u011f\u0131 uzmanlar\u0131n\u0131n kullan\u0131m\u0131 i\u00e7indir. Hasta uygunlu\u011fu, kontrendikasyonlar, prob kullan\u0131m\u0131 ve sonu\u00e7lar\u0131n yorumlanmas\u0131 g\u00fcncel onayl\u0131 kullan\u0131m talimatlar\u0131na ve klinik protokole tabidir.<\/p><\/section><h2>Profesyonel Kullan\u0131m<\/h2><p>Rebound \u00f6l\u00e7\u00fcm\u00fc, topikal anestezik damla kullan\u0131lmadan yap\u0131lacak \u015fekilde tan\u0131mlanm\u0131\u015ft\u0131r. RT-500, onayl\u0131 kullan\u0131m talimatlar\u0131na ve ge\u00e7erli yerel klinik protokole uygun olarak e\u011fitimli g\u00f6z sa\u011fl\u0131\u011f\u0131 profesyonelleri taraf\u0131ndan kullan\u0131lmal\u0131d\u0131r.<\/p>\n<h2>RT-500 S\u0131k Sorulan Sorular<\/h2><h3>RT-500 g\u00f6z i\u00e7i bas\u0131nc\u0131n\u0131 nas\u0131l \u00f6l\u00e7er?<\/h3><p>G\u0130B \u00f6l\u00e7\u00fcm d\u00f6ng\u00fcs\u00fcnde tek kullan\u0131ml\u0131k bir probun kullan\u0131ld\u0131\u011f\u0131 rebound tonometri y\u00f6ntemini kullan\u0131r.<\/p>\n<h3>Farkl\u0131 y\u00f6nlerde \u00f6l\u00e7\u00fcm yap\u0131labilir mi?<\/h3><p>Evet. RT-500 hem dikey hem yatay \u00f6l\u00e7\u00fcm\u00fc destekler.<\/p>\n<h3>Problar nas\u0131l tedarik edilir?<\/h3><p>Belirtilen yap\u0131land\u0131rma 100 tek kullan\u0131ml\u0131k prob i\u00e7erir. \u0130stenen adet ve yedek prob tedariki nihai teklifte belirtilir.<\/p>\n<h3>RT-500 sonu\u00e7lar\u0131 yazd\u0131rabilir mi?<\/h3><p>Evet. Belirtilen yap\u0131land\u0131rma bir kablosuz k\u0131z\u0131l\u00f6tesi termal yaz\u0131c\u0131 i\u00e7erir. Teslim edilecek yaz\u0131c\u0131 ve sarf malzemeleri sipari\u015f kapsam\u0131nda ayr\u0131ca belirtilir.<\/p>\n<h3>Rebound tonometri anestezik g\u00f6z damlas\u0131 gerektirir mi?<\/h3><p>Rebound \u00f6l\u00e7\u00fcm\u00fc, topikal anestezik damla kullan\u0131lmadan yap\u0131lacak \u015fekilde tan\u0131mlanm\u0131\u015ft\u0131r. RT-500 kullan\u0131m talimatlar\u0131na ve yerel klinik protokol\u00fcn\u00fcze uyun.<\/p>\n<h3>Problar yeniden kullan\u0131labilir mi?<\/h3><p>Hay\u0131r. RT-500 tek kullan\u0131ml\u0131k problar kullan\u0131r; belirtilen yap\u0131land\u0131rma 100 adet i\u00e7erir. Yedek prob ihtiyac\u0131 beklenen \u00f6l\u00e7\u00fcm say\u0131s\u0131na g\u00f6re planlan\u0131r, adetler teklifte belirtilir.<\/p>\n<h3>Rebound \u00f6l\u00e7\u00fcmleri Goldmann tonometriyle nas\u0131l kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r?<\/h3><p>Rebound tonometri \u00f6l\u00e7\u00fcm ve taramada yayg\u0131n olarak kullan\u0131l\u0131rken Goldmann aplanasyonu en yayg\u0131n klinik y\u00f6ntem olmaya devam eder. Farkl\u0131 y\u00f6ntemlerin \u00f6l\u00e7\u00fcmleri farkl\u0131l\u0131k g\u00f6sterebilir; bu nedenle bir sonucun ba\u015fka bir y\u00f6ntemle do\u011frulanmas\u0131 gerekip gerekmedi\u011fine hekim karar verir. RT-500&#8217;\u00fcn hassasiyeti 3-25 mmHg aras\u0131nda \u00b11,5 mmHg, 25&#8217;in \u00fczerinden 70 mmHg&#8217;ye kadar \u00b12,5 mmHg&#8217;dir.<\/p>\n<p><a href=\"https:\/\/enochtec.com\/tr\/urunler\/\">Oftalmik ekipman yelpazesini inceleyin<\/a> veya teslimat \u00fclkesi, adet ve kullan\u0131m amac\u0131n\u0131z\u0131 belirterek <a href=\"mailto:sales@enochtec.com\">ENOCHTEC sat\u0131\u015f ekibine e-posta g\u00f6nderin<\/a>.<\/p>\n\n<style id=\"rt500-manual-content-style\">#rt500-workflow,#rt500-operating-settings{scroll-margin-top:24px;margin:32px 0 42px;padding:34px 0 38px;border-top:1px solid #d5e3ed}#rt500-workflow *,#rt500-operating-settings *{box-sizing:border-box;min-width:0;overflow-wrap:break-word}#rt500-workflow .rt500-kicker,#rt500-operating-settings .rt500-kicker,#rt500-workflow .rt500-card-label{font-size:13px!important;line-height:1.5!important;font-weight:700;letter-spacing:.075em;color:#246fa5!important;margin:0 0 15px!important}#rt500-workflow h2,#rt500-operating-settings h2{font-size:36px!important;line-height:1.2!important;text-transform:none!important;color:#173f5b!important;margin:0 0 18px!important;max-width:900px}#rt500-workflow .rt500-lead{color:#506a7f!important;font-size:17px!important;line-height:1.7!important;max-width:790px;margin:0 0 26px!important}#rt500-workflow .rt500-feature-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:20px}#rt500-workflow article{background:#fff;border:1px solid #d1e1ed;border-radius:16px;padding:27px 28px;min-width:0}#rt500-workflow h3{font-size:24px!important;line-height:1.3!important;text-transform:none!important;color:#173f5b!important;margin:0 0 16px!important}#rt500-workflow article>p:last-child{font-size:16px!important;line-height:1.75!important;color:#48657b!important;margin:0!important}#rt500-workflow .rt500-mode-list{margin:0!important}#rt500-workflow .rt500-mode-list>div{display:grid;grid-template-columns:87px minmax(0,1fr);gap:10px;margin-top:10px}#rt500-workflow dt{font-size:14px!important;line-height:1.6!important;font-weight:700;color:#1c567d!important;margin:0!important}#rt500-workflow dd{font-size:15px!important;line-height:1.6!important;color:#48657b!important;margin:0!important}#rt500-operating-settings{border-bottom:1px solid #d5e3ed;margin-top:0;padding-top:30px}#rt500-operating-settings .rt500-settings-table{border:1px solid #d1e1ed;border-radius:14px;overflow:hidden;background:#fff;margin-top:25px}#rt500-operating-settings table,body.postid-13028 .elementor-element-38b576eb table{width:100%;border-collapse:collapse;margin:0;table-layout:fixed;background:#fff!important}#rt500-operating-settings th,#rt500-operating-settings td,body.postid-13028 .elementor-element-38b576eb th,body.postid-13028 .elementor-element-38b576eb td{border:0!important;border-bottom:1px solid #dfe9f1!important;vertical-align:top;padding:17px 20px!important;font-size:16px!important;line-height:1.65!important;overflow-wrap:anywhere;opacity:1!important}#rt500-operating-settings th,body.postid-13028 .elementor-element-38b576eb th{width:48%;text-align:left;background:#f3f7fa!important;color:#43617a!important;font-weight:600}#rt500-operating-settings td,body.postid-13028 .elementor-element-38b576eb td{background:#fff!important;color:#214f70!important}#rt500-operating-settings tr:last-child>*,body.postid-13028 .elementor-element-38b576eb tr:last-child>*{border-bottom:0!important}#rt500-operating-settings .rt500-setting-note,#rt500-workflow .rt500-review-scope{font-size:14px!important;color:#536d80!important;line-height:1.7!important;margin:20px 0 0!important}body.postid-13028 .elementor-element-38b576eb .elementor-widget-container{border-radius:14px;overflow:hidden}@media(max-width:650px){#rt500-workflow,#rt500-operating-settings{margin:26px 0 30px;padding:27px 0 30px}#rt500-workflow h2,#rt500-operating-settings h2{font-size:29px!important}#rt500-workflow .rt500-feature-grid{grid-template-columns:1fr;gap:16px}#rt500-workflow article{padding:23px 21px}#rt500-workflow h3{font-size:23px!important}#rt500-workflow .rt500-lead{font-size:16px!important}#rt500-workflow .rt500-mode-list>div{grid-template-columns:78px minmax(0,1fr);gap:8px}#rt500-operating-settings th,#rt500-operating-settings td,body.postid-13028 .elementor-element-38b576eb th,body.postid-13028 .elementor-element-38b576eb td{font-size:14px!important;padding:14px 13px!important}}<\/style>","protected":false},"excerpt":{"rendered":"<p>3-70 mmHg \u00f6l\u00e7\u00fcm aral\u0131\u011f\u0131, dikey ve yatay \u00f6l\u00e7\u00fcm, tek kullan\u0131ml\u0131k problar ve kablosuz k\u0131z\u0131l\u00f6tesi termal yaz\u0131c\u0131 \u00e7\u0131kt\u0131s\u0131na sahip RT-500 el tipi rebound tonometre.<\/p>\n","protected":false},"featured_media":13029,"menu_order":0,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"product_category":[346,331,355],"class_list":["post-13028","eno_product","type-eno_product","status-publish","has-post-thumbnail","hentry","product_category-portatif-tani-cihazlari","product_category-tani-ve-goruntuleme","product_category-tonometre"],"acf":{"additional_image_1":13030,"additional_image_2":13031,"additional_image_3":13032,"additional_image_4":13033,"additional_image_5":"","additional_image_6":"","additional_image_7":""},"_links":{"self":[{"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/eno_product\/13028","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/eno_product"}],"about":[{"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/types\/eno_product"}],"version-history":[{"count":4,"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/eno_product\/13028\/revisions"}],"predecessor-version":[{"id":15105,"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/eno_product\/13028\/revisions\/15105"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/media\/13029"}],"wp:attachment":[{"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/media?parent=13028"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/enochtec.com\/tr\/wp-json\/wp\/v2\/product_category?post=13028"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}