Full Auto Non contact Tonometer

nCT-Master ST-1000P

Non contact tonometer
Non contact tonometer
Non contact tonometer
NCT1

The full auto non-contact tonometer is an advanced automated eye pressure measurement device designed for fast, accurate, and fully touch-free diagnosis. As an auto non-contact tonometer and high-precision non-contact tonometry device, it uses an innovative air puff tonometer mechanism to deliver consistent and reliable NCT eye pressure measurement for glaucoma screening and comprehensive eye exams.

1. Automated Intraocular Pressure Measurement (IOP)

This fully automated intraocular pressure meter ensures accurate and repeatable results by combining advanced optical sensing with full-auto alignment, tracking, and measurement. The non-contact approach eliminates discomfort and anesthesia, making it ideal for patients of all ages.

2. Pneumotonometer & Rebound Tonometer Reference Compatibility

In addition to air-puff tonometry, the system incorporates reference functions used in pneumotonometers and supports workflows similar to rebound tonometers, providing flexibility across various clinical environments.

3. Corneal Pachymetry & Non-Contact Pachymetry Integration

Accurate corneal pachymetry is essential for interpreting IOP. This device includes a non-contact pachymetry module that measures corneal thickness quickly and safely. Results can be instantly adjusted using built-in pachymetry conversion charts, corneal pachymetry conversion charts, and IOP conversion charts for precise assessment.

4. Corneal Thickness Measurement Device for Enhanced Accuracy

As a comprehensive corneal thickness measurement device, the tonometer helps clinicians adjust IOP values according to corneal biomechanics, ensuring accurate interpretation of pressure readings.

5. Reliable IOP Measurement System for Glaucoma Screening

This advanced IOP measurement system is engineered for early detection of glaucoma and ocular hypertension. It performs rapid and non-contact evaluations, making it an excellent glaucoma screening tonometer for hospitals, clinics, and community health programs.

When it comes to measuring intraocular pressure (IOP) and corneal thickness, there are several essential tools and methods that eye care professionals use. Here’s an overview of the various devices and conversion charts, integrating all relevant keywords:

Non-Contact Pachymetry: Non-contact pachymetry is a technique used to measure the thickness of the cornea without touching the eye. This method is quick and comfortable for patients, making it a popular choice in clinical settings.

Pachymetry Conversion Chart/Table: A pachymetry conversion chart or table is vital for adjusting IOP readings based on corneal thickness. Since thicker or thinner corneas can affect IOP measurements, these charts help provide more accurate readings.

Pneumotonometer and Pneumotonometry: A pneumotonometer measures IOP using a puff of air. This non-invasive method, also known as pneumotonometry or air puff tonometry, is widely used for quick screening in eye clinics.

Rebound Tonometer and Rebound Tonometry: Rebound tonometry involves a small probe that briefly contacts the cornea. This portable device is ideal for various patient groups as it does not require anesthesia.

Corneal Pachymetry Conversion Chart: A corneal pachymetry conversion chart specifically adjusts IOP readings based on the measured corneal thickness, ensuring more precise assessments.

IOP Conversion Chart: An IOP conversion chart helps translate tonometer readings into standardized IOP values, considering individual variations in corneal thickness.

Non-Contact Tonometry (NCT): Non-contact tonometry (NCT) measures eye pressure using a puff of air. This method is painless and efficient, making it suitable for routine eye exams.

Tonometer Eye Pressure Devices: Various devices, including non-contact tonometers, rebound tonometers, and pneumotonometers, are used to measure eye pressure. Each type offers specific advantages depending on the clinical setting and patient needs.

NCT Eye Procedures: NCT eye procedures are non-invasive and do not require numbing drops, making them patient-friendly and efficient for regular screenings.

By utilizing these tools and understanding the importance of pachymetry conversion charts, IOP conversion charts, and corneal pachymetry conversion charts, eye care professionals can ensure precise measurements of eye pressure. These devices and methods are crucial for the early detection and management of conditions like glaucoma, providing comprehensive care for patients.

Overview

The NCT-Master ST-1000P Full Auto Non-Contact Tonometer is an advanced non-contact tonometry device designed for fast, accurate, and fully automated intraocular pressure (IOP) measurement. Using an innovative air puff tonometry mechanism, this system delivers safe, non-invasive, and highly repeatable results, making it ideal for routine eye exams and comprehensive glaucoma screening.

Equipped with a precise non-contact pachymetry module, the device also measures corneal thickness—a critical parameter for interpreting IOP values. To ensure the highest diagnostic accuracy, the tonometer integrates a complete set of pachymetry conversion charts, IOP conversion charts, and corneal pachymetry conversion tables, enabling clinicians to correctly adjust IOP readings according to individual corneal biomechanics.

This automated intraocular pressure meter features full-auto alignment, tracking, and measurement, simplifying the NCT eye procedure for both operator and patient. The fast, touch-free measurement reduces patient discomfort and eliminates the need for anesthetic drops, making it one of the most patient-friendly solutions available.

In addition to air puff tonometry, the system incorporates reference methods such as pneumotonometry (pneumotonometer function) and rebound tonometry compatibility, enabling flexible use in various clinical scenarios. These tonometer eye pressure devices support accurate screening for glaucoma, ocular hypertension, and other ocular conditions requiring reliable IOP monitoring.

The integrated corneal pachymetry function enhances the device’s diagnostic value by providing precise corneal thickness data, which can be instantly applied to the included IOP conversion charts for more accurate assessments. This feature is essential in evaluating glaucoma risk, interpreting atypical pressure values, and ensuring high-quality patient care.

Designed for efficiency and accuracy, this IOP measurement system is ideal for eye clinics, hospitals, community screening programs, and ophthalmology centers that require high-speed operation, reliable measurements, and minimal user intervention. The system’s full automation dramatically enhances workflow, reduces operator dependency, and ensures consistent results across all patient types.

By combining non-contact tonometry, non-contact pachymetry, pachymetry conversion charts, rebound tonometry, and pneumotonometry, this full auto non-contact tonometer provides a complete, modern solution for glaucoma screening, corneal evaluation, and routine ophthalmic diagnostics.

1.Our non contact tonometer comes with Dual sensor system with optic and air blow integrated to provide most precise and reliable IOP result within industry
2.Patent air blow system with softly blow to improve patient comfortability
3.Simply one touch to bring out all tests and results done in both eyes in 30 seconds with fully automatic mode, manual
operation is also optional
4.Easy to use with touch screen and friendly software interface
5.State of the art design for space saving and small examination room
6.IOP correction automatically by corneal thickness ( only in ST-1000P).
7.Data output and transform by USB 2.0 port

Methodology

(Non Contact Tonometer)

Spectral domain OCT

Axial resolution

≤ 6 µm (in tissue)

Transverse resolution

≤ 20 µm (in tissue)

Scan depth

≥ 2.5 mm (in air)

Scan range

≥ 6 mm

Scan speed

≥ 24,000 A-scans/sec, up to 36,000 A-scans/sec

Scan modes

30, Raster, Circle

Fundus image

OCT en face

Focus adjustment

-150 to +150

Pupil diameter

≥ 3 mm

OCT light source

840 nm SLD

Optical power

750 µW (at cornea)

Operation

13.3''touch screen, optional external mouse or keyboard

Power supply

100-240 V, 50/60 Hz

Dimensions 

497 mm × 395 mm × 490 mm (L× W × H)

Weight

LED dot matrix

External fixtion

34 kg (75 lbs)

Automatic NCT ST 1000 2 1

Feel free to contact us, should you have any questions on our non contact tonometer.