Discover Advanced Vision Care with Optical Coherence Tomography (OCT)

OCT-500

Optical Coherence Tomography

Our Optical Coherence Tomography OCT-500 is featured by the overall points below.

Introducing the latest advancement in eye care technology: Optical Coherence Tomography (OCT), a sophisticated imaging system designed to revolutionize the way we diagnose and monitor retinal diseases and other eye conditions.

Unveiling OCT Imaging: Precision and Clarity in Eye Care

Our OCT system offers unparalleled precision with high-resolution retinal scans that provide detailed cross-sectional images of the eye. This non-invasive eye diagnostics tool is pivotal in identifying and managing conditions such as diabetic retinopathy, age-related macular degeneration, and other serious eye diseases.

Comprehensive Retinal Imaging

Optical Coherence Tomography (OCT) excels in retinal imaging, utilizing advanced technology to capture in-depth images of the retina, enabling early detection and ongoing monitoring of eye conditions. Our OCT imaging process is essential for diagnosing complex cases like macular holes and macular edema, conditions that could lead to significant vision loss if untreated.

Enhanced Diagnostic Capabilities

OCT angiography (OCTA) adds another layer of diagnostic power, allowing clinicians to visualize blood vessels in the retina without the need for invasive dyes. This feature is critical in managing diabetic retinopathy and monitoring the blood flow changes associated with macular degeneration. The detailed OCT scans help in assessing retinal thickness and identifying subtle changes that might not be visible with traditional imaging techniques.

Optic Nerve and Eye Disease Screening

Our system not only focuses on the retina but also provides comprehensive optic nerve analysis, essential for detecting glaucoma and other optic nerve-related conditions. The ability to conduct thorough eye disease screening helps in preventive care, ensuring potential issues are addressed before they escalate.

User-Friendly and Efficient

Designed with both the clinician and patient in mind, our OCT equipment is user-friendly and efficient, facilitating a seamless examination experience. The quick and painless procedure enhances visual acuity and patient comfort, making it an ideal choice for regular eye health check-ups.

Why Choose Our OCT Imaging System?

  • Versatility: Effective for both routine screenings and in-depth diagnostic needs.
  • Precision: Delivers precise imaging results that are crucial for accurate diagnosis.
  • Efficiency: Reduces examination time and increases patient throughput without compromising quality.
  • Patient Comfort: Minimizes discomfort with non-invasive scanning technology.

Equip your practice with our cutting-edge Optical Coherence Tomography system to enhance diagnostic capabilities and improve patient outcomes. Whether it’s detecting early signs of macular degeneration or conducting comprehensive diabetic retinopathy detection, our OCT system is designed to meet the diverse needs of modern eye care professionals.

For more information on how our Optical Coherence Tomography system can benefit your practice, or to schedule a demonstration, contact us today. Take the next step in eye care excellence with our state-of-the-art OCT imaging solutions.

smiley, eyes, happy-39984.jpg

Compact Design

Everything is inside this compact body. No external computer is needed. Plug in the power cable, then you are ready to go.

man, adult, businessman-1459246.jpg

PC Inside

Data acquisition and processing are accomplished by the internal computer. The data can be transported via Ethernet or external hard drive. Peripheral devices, such as keyboard or printer, can be connected to the computer ports.

icon, cross, work-2381943.jpg

Easy Installation

No complex connection or setup. Compact body can fit in even small space.


label, sale, icon-2016248.jpg

Affordable Quality

We believe that less is more. The simple design of OCT-500 reduces the cost of the device without sacrificing the image quality.

Optical Coherence Tomography has never been so affordable.

optical coherence tomography OCT-500 is quite a versatile device for measuring and describing a series of scans which are taken to visualize and determine the thickness of a structure in the eye. This is usually the retina at the back of the eye or the cornea at the front of the eye.

  • All-in-one design with optional larger external monitor guarantees an installation-free experience.Plug the power cable and power on the system,then you are ready to go.
  • Fully automated operation with minimum human intervention. Smart pupil alignment, advanced signal optimization assure quality OCT images independent of operators.
  • The small footprint and all-in-one system fits in the smallest examination room. The flexible monitor locations allows various operator positions.
  • Extremely easy to operate. Make for professionals without professional operators.
  • High definition image and comprehensive analysis software.
  • Subtle lesion will be precisely identified via high resolution image.
  • With more than 4 scan mode on macular and opticpart, the software creates a summary analysis of macula retina, RNFL,ONH. Progress analysis for follow-up examination is available.

Specifications:

Methodology

Spectral domain OCT

Axial resolution

≤ 6 µm (in tissue)

Transverse resolution

≤ 20 µm (in tissue)

Scan depth

≥ 2.5 mm (in air)

Scan range

≥ 6 mm

Scan speed

≥ 24,000 A-scans/sec, up to 36,000 A-scans/sec

Scan modes

30, Raster, Circle

Fundus image

OCT en face

Focus adjustment

-150 to +150

Pupil diameter

≥ 3 mm

OCT light source

840 nm SLD

Optical power

750 µW (at cornea)

Operation

13.3’’touch screen, optional external mouse or keyboard

Power supply

100-240 V, 50/60 Hz

Dimensions 

497 mm × 395 mm × 490 mm (L× W × H)

Weight

LED dot matrix

External fixtion

34 kg (75 lbs)

Our OPTICAL COHERENCE TOMOGRAPHY OCT-500 is very easy to operate. You may refer to the steps below for more information. Feel free to reach out to us for more technical details or quotation related issues.

simple operation