YDC-3100 Non-Mydriatic Fundus Camera

Model

YDC-3100

YDC-3100 non-mydriatic fundus camera with 5 MP imaging, a 50° single-image field, automatic and manual controls, and DICOM 3.0 support. Nine-image mosaic provides a composite view of up to 135°.

Need help selecting a configuration?
Tell us your market, clinical workflow and project requirements.

Product Highlights

Key Features

5-megapixel photography with a 50° single-image field of view. One-key sequential photography of both eyes with automatic chinrest adjustment, pupil searching, alignment, focus and exposure. Automatic and manual operation, focus and exposure. Nine-position mosaic: up to 135° composite coverage from nine 50° images, not a single exposure. Minimum pupil size ≥2.8 mm; 13 mm working distance; ±25 D diopter compensation. Brightness, gamma, contrast and RGB image adjustment. Soft-illumination workflow and lesion-area / cup-to-disc-ratio software tools are described; quantitative light data, method, validation and software-version scope require confirmation. DICOM 3.0 support and customizable AI interface; integration and licence scope require confirmation.
Clinical Use

Applications

Professional fundus photography, retinal image documentation and image review in ophthalmology clinics and hospital eye-care departments. Non-mydriatic or mydriatic acquisition is selected according to the patient, approved instructions for use and clinician’s protocol. No diagnosis or clinical outcome is guaranteed.

50° Fundus Imaging with Automatic and Manual Control

The YDC-3100 non-mydriatic fundus camera combines 5-megapixel photography with a 50° single-image field of view for professional retinal image documentation. Its acquisition modes include non-mydriatic and mydriatic photography, with automatic and manual focus, exposure and operation.

One-Key Workflow and Manual Adjustment

The automatic workflow supports chinrest adjustment, pupil searching, alignment, focusing and exposure, followed by sequential photography of both eyes through a one-key command. A dual-camera system assists autofocus and pupil location. The brochure describes this workflow without specifying a guaranteed acquisition time.

Manual operation is available when the automatic mode is not suitable or a particular area needs to be photographed. Touchscreen controls allow the operator to adjust alignment, focus, flash and diopter compensation.

Single Images and Nine-Position Mosaic

Each source image has a 50° field of view. The nine-position mosaic function combines nine 50° images into a composite view of up to 135°. This is a multi-image mosaic, not a 135° single exposure. Confirm mosaic software availability and the selected workflow in the quotation.

Pupil Size and Patient Preparation

The listed minimum pupil size is ≥2.8 mm, with a 13 mm working distance and ±25 D diopter compensation. Non-mydriatic capability does not guarantee that every patient can be imaged without dilation. Patient preparation and image assessment remain subject to the approved instructions for use and the responsible clinician’s judgement.

The brochure also describes a soft-illumination workflow intended to reduce illumination-related pupil constriction and permit two consecutive exposures. No quantitative illumination level, exposure interval or guaranteed patient response is specified; confirm the current operating instructions and selected configuration.

Image Processing and Data Integration

Image-processing controls include brightness, gamma, contrast and RGB adjustment. The brochure also describes lesion-area measurement and cup-to-disc-ratio tools; their method, validation, diagnostic use and software-version scope are not specified, so confirm them in the quotation and approved documentation. The brochure lists DICOM 3.0 support, PACS connection, real-time LAN sharing, USB storage expansion and FTP transfer. Confirm the required software, licences, network implementation, security and compatibility with the receiving system before ordering.

A customizable AI interface is listed. This is an integration option; it does not establish that an AI diagnostic system, algorithm, licence or regulatory clearance is included. Any AI-related scope requires a separate configuration review.

YDC-3100 Questions Before Ordering

Is the field of view 50° or 135°?

The single-image field of view is 50°. A mosaic of nine images can provide a composite view of up to 135°; it is not a single-shot 135° field.

Does the camera support manual operation?

Yes. Automatic and manual focus, exposure and operation are listed. Manual touchscreen adjustment covers alignment, focus, flash and diopter compensation.

Does every examination avoid dilation?

No. Both non-mydriatic and mydriatic acquisition modes are listed. The clinician determines the appropriate preparation and whether an image is adequate for the intended examination.

Are hospital integration and AI included?

DICOM 3.0 and a customizable AI interface are listed capabilities. The actual software, licences, receiving-system compatibility and implementation must be confirmed for the order; AI diagnosis is not assumed to be included.

Request a YDC-3100 Configuration

Contact ENOCHTEC sales with your country, quantity, intended examination setting and image-management requirements. Confirm the current model-specific specification, workstation, accessories, software, training, service and destination-market documentation in the quotation. Specifications and design are subject to change.

Project Fit

Configurations & Options

Confirm the imaging unit, SLR camera configuration, controls, workstation, mosaic software, DICOM/PACS implementation, LAN/USB/FTP workflow, licences, accessories, operating documentation, installation, training, service and destination-market requirements in the quotation. A customizable AI interface is described; AI diagnostic software, algorithms, licences and regulatory clearance are not assumed included.

Final configurations, accessories and documentation are confirmed according to market and project requirements.

Technical Specifications

Specification YDC-3100
Acquisition modes Non-mydriatic / mydriatic
Single-image field of view 50°
Mosaic field of view Up to 135° from nine 50° images; multi-image mosaic, not a single exposure
Working distance 13 mm
Minimum pupil size ≥2.8 mm
Focus modes Auto / manual
Exposure modes Auto / manual
Operation Auto / manual
Photography SLR camera
Resolution 5 megapixels
Diopter compensation ±25 D
Fixation Internal fixation
Autofocus assistance Dual camera
DICOM 3.0 Supported; implementation and receiving-system compatibility to be confirmed
Data interfaces and transfer PACS connection, LAN sharing, USB storage expansion and FTP transfer are described; confirm implementation and software scope
Customizable AI interface Available for customization; no AI diagnostic system or licence assumed included
Image-analysis tools Lesion-area measurement and cup-to-disc-ratio tools are described; method, validation, diagnostic use and software-version scope to be confirmed
Dimensions (L × W × H) 280 × 559 × 460 mm
Weight 21 kg
Power supply 100–240 V, 50/60 Hz

Specifications and design are subject to change. Confirm the current model-specific specification, software and configuration in the approved quotation.

Discuss This Product with ENOCHTEC

Request specifications, configuration guidance or a distributor quotation for your market.

Product Questions & Buying Guidance

Practical answers for clinics, hospitals, distributors and project buyers evaluating this product. Final configurations are confirmed for the destination market and intended workflow.

What information is needed for an accurate quotation?

Please share the destination country, intended clinical use, expected quantity, preferred configuration, local power standard and any required regulatory or tender documents. This lets ENOCHTEC prepare the most relevant technical and commercial proposal.

Yes. Available accessories, interface options, language, power standard, documentation and room integration can be reviewed for the destination market. Any change remains subject to the selected model, order quantity and regulatory requirements.

ENOCHTEC can support model selection, portfolio planning, technical documentation, product positioning and after-sales coordination for distributor and project orders. Training scope and service arrangements are confirmed according to the product and market.