Surgical Equipment · Cataract
MD-480A Phacoemulsification System
Phaco Machine for Cataract Surgery
A touchscreen-controlled phaco emulsifier combining four ultrasound modes, peristaltic aspiration and irrigation, with anterior vitrectomy and bipolar cautery in one console.
For trained ophthalmic surgical teams. Configuration, accessories and destination-market documentation are confirmed with the quotation.
Ultrasound, aspiration & console control
A focused platform for cataract surgery
Review the working mode, adjust parameters and recall preferred settings from the colour touchscreen.
01 / ULTRASOUND
Four modes to suit the surgical plan
Select continuous, linear, pulse or burst ultrasound delivery. Digital frequency tuning matches the U/S handpiece to the console.
02 / ASPIRATION
Peristaltic flow control
Set aspiration flow and the vacuum limit separately. The touchscreen shows operating values while the footswitch controls irrigation, aspiration and ultrasound stages.
03 / WORKING SETTINGS
Save and recall preferred parameters
Store up to ten groups of working parameters for each U/S, VIT, cautery and I/A mode, then recall a saved set from the console.
04 / SYSTEM CHECKS
Test the tubing and handpiece
The automatic TEST routine checks for tubing blockage, leakage and handpiece-matching problems. On-screen messages and audible prompts support setup review.
Anterior-segment support
Anterior vitrectomy and bipolar cautery are available alongside U/S and I/A modes. Accessories and handpieces are selected for the agreed configuration.
Footswitch-led operation
A three-stage treadle controls irrigation, aspiration and the selected working function, with separate reflux and cautery switches.
Technical data
Technical Specifications
Operating ranges and console functions for the MD-480A.
Ultrasound & aspiration
- Model
- MD-480A
- Ultrasound frequency
- 40 kHz ±20%
- Ultrasound modes
- Continuous, linear, pulse and burst
- Ultrasound power setting
- 0–100%; 1% increments
- Pulse frequency
- 1–99 Hz; 1 Hz increments
- Pulse duty-cycle setting
- 1–99%; minimum on-time 5 ms
- Burst pulse width
- 5–100 ms; 1 ms increments
- Maximum vacuum
- 500 mmHg (66.7 kPa)
- Aspiration flow setting
- 1–40 mL/min
Console, support modes & installation
- Pump type
- Peristaltic
- Parameter memory
- 10 groups per working mode
- Anterior vitrectomy
- Single-cut mode or 20–600 cuts/min
- Bipolar cautery frequency
- 1 MHz ±20%
- Maximum cautery output
- 10 W ±20% at 200 Ω
- Cautery output setting
- 0–100%; 1% increments
- Power supply
- AC 100–240 V, 50/60 Hz ±2%
- Operating temperature
- 10–30 °C
- Operating relative humidity
- ≤70%
Working-mode ranges & defaults
- Linear mode default power
- 50%
- Pulse mode default
- 10 Hz; 50% duty cycle
- Burst mode default
- 30 ms pulse width
- Vitrectomy default
- 400 cuts/min
- Vitrectomy cut setting
- 1–19: single cut; 20–600: continuous cutting (cuts/min)
- Reflux (reverse aspiration)
- 20 mL/min ±20%; up to 1 s
Additional console functions
- Anterior chamber protection
- Sensitivity levels 1–9
- Handpiece tuning
- Automatic (TUNE)
- Cleaning
- Automatic CLEAN function
- Live display
- Vacuum and ultrasound power
- Ultrasound time
- Accumulated time (UST/APT)
- Footswitch feedback
- Audible cue at each pedal-position change
Safety classification
- Reference standards
- IEC 60601-1; IEC 60601-1-2
- Equipment class
- Class I
- U/S handpiece, vitrector, I/A handpiece
- Type B applied parts
- Bipolar cautery forceps
- Type BF applied part
- Footswitch
- IPX8 (waterproof)
Installation, storage & duty cycle
- Irrigation bottle height
- 20–90 cm above the vacuum-sensing port
- Unstable mains supply
- Use a regulated supply of at least 500 W
- Power cord length
- 3 m maximum
- Storage and transport
- −10 to 45 °C; ≤80% relative humidity
- Duty cycle
- 30 min continuous operation, then 20 min rest
Values describe the specified operating ranges; they do not represent recommended surgical settings. The trained clinical team selects parameters and follows the current instructions for use.
Cataract equipment planning
Build around the cataract workflow
Combine pre-operative biometry, surgical visualisation and microsurgical instruments around your phacoemulsification setup.
INTRA-OPERATIVE EQUIPMENT
01 / Measure & plan
AL-VIEW Lite
Optical biometry for pre-operative measurements and IOL planning.
02 / Surgical visualisation
SM-2000L
Ophthalmic surgical microscopy for the surgeon’s view during the procedure.
03 / Microsurgical instruments
21-Piece Cataract Set
Microsurgical scissors, forceps and hand instruments, with titanium-alloy and stainless-steel options.
Configure the equipment
Match the console and accessory package to the intended workflow.
Plan consumables
Confirm handpieces, tips, sleeves and compatible tubing before ordering.
Prepare for continued use
Review reprocessing, training, spares and service arrangements.
This illustrates equipment planning across the workflow. Device interfaces and supply packages are confirmed separately. IOLs, other surgical instruments and consumables are planned according to the facility’s requirements.
For pre-operative axial length and IOL power calculation, pair the MD-480A with the MD-1000A/P A-scan biometer and pachymeter.
Configuration & buying guidance
Plan the complete working setup
Accessory package to confirm
- U/S handpiece, tip, sleeve and test chamber
- I/A handpiece and compatible irrigation/aspiration tubing
- Vitrector and bipolar cautery forceps (standard)
- Footswitch and the required setup accessories
Details for an accurate quotation
- Destination country, quantity and expected workload
- Local power supply and required documentation
- Consumable quantities and replenishment plan
- Reprocessing, training and service requirements
Standard accessory specifications
- U/S handpiece: 01-899145B
- Vitrector: 4420CE
- I/A handpiece: 607006 (0.3 mm, straight)
- Footswitch: FTS-480A
- U/S tip: LT30 (19G, 30°)
- Silicone tubing: two sizes, 1.8 m each
- Part numbers follow the factory configuration; the written quotation confirms the items supplied.
Reprocessing, reuse & warranty
- Handpieces, vitrector and tips can be autoclaved following the instructions for use
- Silicone parts (sleeves, test chamber, tubing) can be reused up to 20 times
- Replace tips when they become dull
- Warranty: 1 year for the console, 6 months for the U/S handpiece; tips, wrench, test chamber and irrigation sleeves are not covered
- Final terms are confirmed in the written quotation.
The CLEAN function supports handpiece and tubing cleaning; cleaning is followed by the prescribed disinfection and sterilisation process. Use manufacturer-specified accessories and current reprocessing instructions.
Buying guidance
MD-480A product questions
What is the MD-480A used for?
The MD-480A phacoemulsification machine is intended for cataract extraction. It combines ultrasonic emulsification with irrigation and aspiration, with anterior-segment vitrectomy and bipolar cautery functions.
Which ultrasound modes are available?
Continuous, linear, pulse and burst modes are available. Mode and parameter selection are made by the trained surgical team for the procedure.
Does it include a vitrectomy function?
It supports anterior-segment vitrectomy with single-cut and 20–600 cuts/min settings. This function should not be interpreted as a complete posterior-segment or retinal surgery platform.
What affects the phaco machine price?
The quotation depends on the agreed console and handpiece package, tips and sleeves, tubing, footswitch, documentation, order quantity and delivery terms. Share the destination country and expected case volume for a configuration-specific proposal.
What should be confirmed before ordering?
Confirm the local electrical supply, approved accessory and consumable package, reprocessing requirements, destination-market documentation, training and service arrangements. The accessories shown in the product images are supplied as standard; the written quotation lists the final scope of supply.
Does the MD-480A work on 110 V and 220 V power?
Yes. The MD-480A accepts 100–240 V AC, 50/60 Hz. If the local supply is unstable, use a regulated supply of at least 500 W. The plug type and power cord for your market are confirmed in the quotation.
Can the handpieces and tips be autoclaved?
The U/S and I/A handpieces, vitrector and tips can be steam-sterilised in an autoclave following the current instructions for use. Silicone parts (sleeves, test chamber and tubing) can be reused up to 20 times; replace tips when they become dull.
What warranty does the MD-480A have?
The standard warranty is 1 year for the console and 6 months for the U/S handpiece. Tips, wrench, test chamber and irrigation sleeves are consumable items and are not covered. Final warranty terms are stated in the written quotation.
Which consumables need regular replacement?
Phaco tips, irrigation sleeves, the test chamber and tubing are consumables. Silicone parts can be reused up to 20 times according to the manual; replace tips when they become dull. Share your case volume for a replenishment plan.
Which interface languages are available?
The touchscreen interface is available in Chinese and English; other interface languages can be evaluated for your target market.
Discuss your MD-480A setup.
Share your destination market, case volume and required accessories for a configuration-specific proposal.