RetiMINER-P all-in-one visual electrophysiology system with monitor, keyboard and mouse on a table
ENOCHTEC · PROFESSIONAL EYE-CARE EQUIPMENT

RetiMINER-P Visual Electrophysiology System (VEP, ERG, EOG)

Model

RetiMINER-P

The ENOCHTEC RetiMINER-P is an all-in-one visual electrophysiology system for pattern VEP, flash VEP, pattern ERG, flash ERG and EOG. The amplifier, flash stimulator and pattern stimulator are built into one host with a single power cord and monitor cable, and the subject stays in one test position.

Need help selecting a configuration?
Tell us your market, clinical workflow and project requirements.

RetiMINER-P all-in-one visual electrophysiology system with monitor, keyboard and mouse on a table
Product Highlights

Key Features

  • All standard ISCEV programs: pattern VEP, flash VEP, pattern ERG, flash ERG and EOG.
  • Integrated host: amplifier, flash and pattern stimulators in one unit; one power cord and one monitor cable.
  • Rotating visor turns the pattern stimulator into a Ganzfeld dome, with built-in fixation and EOG LEDs.
  • Infrared camera for fixation and electrode monitoring; motorized chin support.
  • 24-bit DC amplifier with optically isolated USB and full real-time digital filters.
  • Offline averaging with manual sweep rejection and user-defined filters.
  • Embedded Linux computer; PDF and JPG export, network sharing and optional DICOM.
Clinical Use

Applications

  • Assessment of retinal function with flash and pattern ERG.
  • Assessment of the visual pathway with pattern and flash VEP.
  • EOG testing of the outer retina and retinal pigment epithelium.
  • Infant examinations and research recordings with offline signal rejection and filtering.
  • Ophthalmology clinics, hospital eye departments, neurology units and research laboratories.

RetiMINER-P All-in-One Visual Electrophysiology System

The ENOCHTEC RetiMINER-P is an all-in-one visual electrophysiology system for ISCEV-standard pattern VEP, flash VEP, pattern ERG, flash ERG and EOG. The DC amplifier, flash stimulator, pattern stimulator and EOG indicators are built into a single host, so the whole system needs only one power cord and one monitor cable and the subject stays in the same test position for every test.

What Does Visual Electrophysiology Measure?

  • VEP depends on the functional integrity of central vision at every level of the visual pathway: eye, retina, optic nerve, optic radiations and occipital cortex.
  • ERG and flash ERG mainly reflect the function of rods, cones and the connected bipolar cells; the rod and cone systems can be isolated by dark and light adaptation.
  • Pattern ERG represents the function of the ganglion cells when the photoreceptors and bipolar cells work normally.
  • EOG tests the function of the outer retina and the retinal pigment epithelium.

Integrated Design

Conventional systems consist of a separate computer, pattern stimulator, amplifier and flash stimulator joined by cables, which occupy a lot of room and are hard to move. The RetiMINER-P integrates all of them. A knob on top rotates a visor with a diffuse reflective surface over the pattern stimulator and turns the unit into a complete Ganzfeld dome for flash stimuli. The visor carries a built-in fixation LED and two EOG LEDs, so EOG testing is supported without extra equipment.

ISCEV Programs and Fixation Monitoring

The software includes all standard ISCEV programs. An infrared camera shows the subject’s face during pattern, flash and EOG tests, so the operator can check whether the electrodes work properly, whether unexpected eye movement occurs, whether the other eye is covered (for VEP) and whether the subject is becoming fatigued. A motorized chin support is controlled from the software.

Stimulators and Amplifier

The flash stimulator provides white, red, green and blue light and their combinations, with a 30 cd·s/m² broad-band white flash in under 4 ms, single, double and string flashes, and a background of 0–500 cd/m². The pattern stimulator offers checkerboard, horizontal and vertical stripes and rectangle patterns with adjustable element angle, up to 250 cd/m² luminance and more than 98% contrast, and a wide choice of stimulus fields. The DC amplifier has a 24-bit A/D converter, an optically isolated USB 2.0 connection and full real-time digital filters.

Offline Averaging and Digital Signal Processing

The amplifier records the bio-signal over the full frequency band and the software filters it digitally. After the test, the operator can manually reject sweeps contaminated by eye or muscle movement, which is useful for infant examinations and medico-legal records, and can define new filters and run spectral analysis on the recorded signal. Dark-toned software and a dark-red illumination and screen mode suit work in a darkroom.

Embedded Computer and Reports

The system uses a card-sized embedded computer with open-source Linux, with no hard disk, graphics card or memory sticks, which keeps the system simple and avoids common PC viruses. The multi-language interface is developed in-house. Reports can be exported as PDF or JPG and shared over the network; DICOM connection to a PACS or HIS (fetching patient data and exam instructions, uploading reports) is available as an option.

RetiMINER Models

RetiMINER-P RetiMINER-C RetiMINER Animal
Intended use Clinical ERG, VEP and EOG Clinical and research ERG, VEP and EOG Animal ERG and VEP research
Design All-in-one host Separate stimulators on a movable motorized table Animal platform with 90° cantilever flash stimulator
Flash stimulator Built-in, 30 cd·s/m² LightBurst, 100 cd·s/m² LightBurst, 100 cd·s/m²
Pattern stimulator Built-in LCD Optional
Test position Single fixed position Seated, lying or infant subjects; bedside use possible Animal on the platform
Animal testing — Optional add-on Dedicated system

What Should Buyers Confirm Before Ordering?

Confirm the tests required (pattern VEP, flash VEP, pattern ERG, flash ERG, EOG), the optional DICOM connection, the interface and report language, the electrode sets and consumables, and the installation space. The final supply configuration is confirmed in the written quotation. Request a quotation for the RetiMINER-P.

Frequently Asked Questions

Which tests does the RetiMINER-P perform?

Pattern VEP, flash VEP, pattern ERG, flash ERG and EOG, covering all standard ISCEV programs.

Does it need a separate computer or amplifier?

No. The amplifier, flash and pattern stimulators and the embedded computer are in one host; only a power cord and a monitor cable are connected.

Can the subject stay in one position?

Yes. Flash, pattern and EOG stimulation are all in the same host, so the subject does not need to be moved between stimulators and the amplifier does not need to move with the patient.

Can it connect to a PACS or HIS?

Yes, as an option. DICOM connection can fetch patient files and exam instructions from the HIS and upload reports; reports can also be exported as PDF or JPG.

See the Visual Electrophysiology range for related systems. Interpretation of results remains the responsibility of the examining clinician.

Project Fit

Configurations & Options

Standard supply includes the all-in-one main unit and the software; electrode sets and the DICOM interface are options. Confirm the tests required, interface and report language, electrodes and installation space before quotation. Final inclusions follow the written quotation.

Final configurations, accessories and documentation are confirmed according to market and project requirements.

Technical Specifications

Mainframe
Product type All-in-one integrated host, few wires, easy to install and use
Subject placement Single position; pattern, flash and EOG tests at the same location
Patient monitoring Infrared surveillance camera; face visible in the software during pattern, flash and EOG tests
Chin support Software-controlled motorized chin support
Amplifier
Input impedance ≥1000 MΩ
CMRR ≥115 dB
Input noise ≤4 µVpp
A/D resolution 24 bit
Port Optically isolated USB 2.0; powered by USB
Filter Full real-time digital filter: band-pass, band-stop, high-pass, low-pass, comb
Flash stimulator
Light source White, red, green, blue and any combination
Flash luminance 30 cd·s/m² broad-band white flash in <4 ms
Stimuli mode Single, double, string, on/off; on duration adjustable
Background illumination 0–500 cd/m²
Stimuli frequency 0.01–200 Hz
Flash range 0–100 cd·s/m²
Fixation and EOG 3 fixation/EOG indicators
Pattern stimulator
Luminance 0–250 cd/m²
Contrast >98%
Pattern Checkerboard, horizontal/vertical stripes, rectangle; adjustable element angle
Stimulus field Full field; left, right, upper or lower half; up-down or left-right margin; quarter fields; horizontal or vertical centre; 1/8 centre; centre circle or outside field at any angle
Computer system
Computer Embedded card-sized computer
Operating system Open-source Linux
Software Self-developed, multiple-language interface
Test utility Dark-red illumination; dark-red screen; light/dark adaptation timer
E-report PDF/JPG export; network share; DICOM (optional)

Discuss This Product with ENOCHTEC

Request specifications, configuration guidance or a distributor quotation for your market.

Product Questions & Buying Guidance

Practical answers for clinics, hospitals, distributors and project buyers evaluating this product. Final configurations are confirmed for the destination market and intended workflow.

What information is needed for an accurate quotation?

Please share the destination country, intended clinical use, expected quantity, preferred configuration, local power standard and any required regulatory or tender documents. This lets ENOCHTEC prepare the most relevant technical and commercial proposal.

Yes. Available accessories, interface options, language, power standard, documentation and room integration can be reviewed for the destination market. Any change remains subject to the selected model, order quantity and regulatory requirements.

ENOCHTEC can support model selection, portfolio planning, technical documentation, product positioning and after-sales coordination for distributor and project orders. Training scope and service arrangements are confirmed according to the product and market.