RetiMINER Animal ERG and VEP system with LightBurst flash stimulator, animal platform and monitor
ENOCHTEC · PROFESSIONAL EYE-CARE EQUIPMENT

RetiMINER Animal ERG and VEP System

Model

RetiMINER Animal

The ENOCHTEC RetiMINER Animal is an animal ERG and VEP system for preclinical vision research. It has a 90° cantilever LightBurst flash stimulator, an acrylic platform with a magnetic electrode holder and a supplied USB heated blanket, and predefined animal protocols for pattern VEP, flash VEP, pattern ERG and flash ERG. The standard set-up suits mice and rats. For research use.

Need help selecting a configuration?
Tell us your market, clinical workflow and project requirements.

RetiMINER Animal ERG and VEP system with LightBurst flash stimulator, animal platform and monitor
Product Highlights

Key Features

  • Acrylic animal platform with a slot for the supplied USB heated blanket and a magnetic electrode holder.
  • 90° cantilever LightBurst flash stimulator, 100 cd·s/m² in under 4 ms.
  • Predefined protocols for pattern VEP, flash VEP, pattern ERG and flash ERG; custom protocols.
  • Standard set-up for mice and rats; also beagles (customised), monkeys, pigs, rabbits and zebrafish.
  • Electrodes supplied: 2 gold ring, 1 needle, 1 tail clamp.
  • Export to PDF, DAT (32-bit float) and CSV for Python, R, Igor and GraphPad.
  • Optional ultraviolet stimulation, pattern stimulator and DICOM.
Clinical Use

Applications

  • Preclinical ERG and VEP studies of retinal and optic nerve function.
  • Disease-model and treatment studies of retinal and optic nerve function in mice and rats.
  • Research recordings in beagles, monkeys, pigs, rabbits and zebrafish.
  • University and hospital research laboratories.

RetiMINER Animal ERG and VEP System for Preclinical Research

The ENOCHTEC RetiMINER Animal is an animal ERG and VEP system for vision research. It combines the LightBurst flash stimulator on a 90° cantilever, an acrylic animal platform with a magnetic electrode holder and predefined protocols for pattern VEP, flash VEP, pattern ERG and flash ERG. The system is intended for research use.

Platform Designed for Animal Studies

  • Acrylic animal platform with a slot for the supplied USB heated blanket, which keeps the body temperature of anaesthetised animals stable. The heating is not built into the platform, so a damaged or soiled blanket is easily replaced.
  • Magnetic swivel electrode holder for quick, repeatable electrode placement. Angle and orientation can be adjusted to different eye positions while avoiding excessive corneal pressure, which could cause cataracts.
  • 90° cantilever flash stimulator that positions the LightBurst over the eye of the animal. Lift the flash bowl to dilate pupils, anaesthetise and install electrodes under the dim red light inside the bowl, then lower it for the test; an embedded infrared camera monitors the animal and the electrodes.
  • Electrodes supplied: two gold ring electrodes, one needle electrode and one tail clamp. For mice and rats the default set-up is the tail clamp as ground, the needle as reference (shared by both eyes) and the gold rings as working electrodes; for other animals and set-ups please contact us.

Species Supported

The standard platform and electrodes are designed for common laboratory animals such as mice and rats. The system is also used for beagles (customised product) and monkeys, and is suitable for recording ERG and VEP in pigs, rabbits, zebrafish and other animals. Predefined flash ERG protocols are provided for zebrafish, and custom protocols can be created for other species and study designs.

Predefined Protocols

Protocol Setting
Pattern VEP Animal pattern reversal, 1° check size
Flash VEP Predefined animal protocol
Pattern ERG Predefined animal protocol
Flash ERG, dark-adapted 0.001–100
Flash ERG, light-adapted 1–100
Flash ERG, zebrafish 0.01–10

Custom protocols can be created and saved, which suits long-running studies that need identical settings across animals and time points.

Stimulators

The LightBurst flash stimulator delivers 100 cd·s/m² in under 4 ms in white, red, green, blue and yellow, with ultraviolet as an option, a flash range of 0–1000 cd·s/m², a background of 0–3000 cd/m² and a stimulus frequency of 0.01–200 Hz. A pattern stimulator (0–250 cd/m², contrast above 98%) is optional for pattern ERG and pattern VEP and comes with a universal support bracket for adjusting its distance and angle to the eyes of the animal.

Host and Software

The computer and power supply are built into the host box, so no external computer is needed and wiring stays simple. A blackout cloth between the monitor and the animal platform keeps the room dark. The dark-toned software lets operators switch the test eye with one click during VEP, and animal numbers can be generated automatically by configurable rules.

For repeatable VEP recordings in mice, implanted active electrodes are recommended; please contact us for electrode preparation and recording methods.

Data Export for Research

Recordings can be exported as PDF reports, as DAT files (32-bit float) that open in Python, R, Igor and GraphPad, and as CSV, so waveforms can be analysed in the statistics software of your laboratory. DICOM connection is available as an option.

RetiMINER Models

RetiMINER-P RetiMINER-C RetiMINER Animal
Intended use Clinical ERG, VEP and EOG Clinical and research ERG, VEP and EOG Animal ERG and VEP research
Design All-in-one host Separate stimulators on a movable motorized table Animal platform with 90° cantilever flash stimulator
Flash stimulator Built-in, 30 cd·s/m² LightBurst, 100 cd·s/m² LightBurst, 100 cd·s/m²
Pattern stimulator Built-in LCD Optional
Test position Single fixed position Seated, lying or infant subjects; bedside use possible Animal on the platform
Animal testing — Optional add-on Dedicated system

What Should Buyers Confirm Before Ordering?

Confirm the species and protocols needed, whether ultraviolet stimulation and a pattern stimulator are required, the electrode types and the data formats for your analysis. The final supply configuration is confirmed in the written quotation. Request a quotation for the RetiMINER Animal.

Frequently Asked Questions

Which animals can be tested?

The standard platform is designed for mice and rats. Beagles (customised), monkeys, pigs, rabbits, zebrafish and other animals are also suitable; please contact us about the electrode set-up for your species.

Can the body temperature of the animal be maintained?

Yes. The system comes with a USB heated blanket that sits in the slot of the acrylic platform and can be replaced easily if it is damaged or soiled.

Which data formats can I export?

PDF reports, DAT (32-bit float) and CSV. DAT files open in Python, R, Igor and GraphPad.

Is it for clinical use?

No. The RetiMINER Animal is a research system. For human testing see the RetiMINER-P and RetiMINER-C.

See the Visual Electrophysiology range for related systems.

Project Fit

Configurations & Options

Standard supply includes the animal platform with magnetic electrode holder, 90° cantilever flash stimulator, amplifier, electrodes (2 gold ring, 1 needle, 1 tail clamp), USB heated blanket and software with predefined protocols. Options include ultraviolet stimulation, a pattern stimulator and DICOM connection. Final inclusions follow the written quotation.

Final configurations, accessories and documentation are confirmed according to market and project requirements.

Technical Specifications

Platform
Platform Acrylic animal platform with slot for the supplied USB heated blanket
Electrode holder Magnetic
Electrodes 2 gold ring, 1 needle, 1 tail clamp
Amplifier
Input impedance ≥1000 MΩ
CMRR ≥115 dB
Input noise ≤4 µVpp
A/D resolution 24 bit
Port Optically isolated USB 2.0; powered by USB
Filter Full real-time digital filter: band-pass, band-stop, high-pass, low-pass, comb
Flash stimulator
Mounting 90° cantilever
Colours White, red, green, blue, yellow; ultraviolet optional
Flash intensity 100 cd·s/m² in <4 ms
Flash range 0–1000 cd·s/m²
Background illumination 0–3000 cd/m²
Stimuli frequency 0.01–200 Hz
Fixation and EOG 11 indicators, adjustable in 64 levels
Pattern stimulator Optional; 0–250 cd/m²; >98%
Predefined protocols
Pattern VEP Animal pattern reversal, 1°
Flash VEP Predefined
Pattern ERG Predefined
Flash ERG Dark-adapted 0.001–100; light-adapted 1–100; zebrafish 0.01–10
Custom protocols Supported
Species and data
Species Standard set-up for mice and rats; beagles (customised) and monkeys; also suitable for pigs, rabbits and zebrafish
Data export PDF; DAT (32-bit float; Python, R, Igor, GraphPad); CSV
DICOM Optional

Discuss This Product with ENOCHTEC

Request specifications, configuration guidance or a distributor quotation for your market.

Product Questions & Buying Guidance

Practical answers for clinics, hospitals, distributors and project buyers evaluating this product. Final configurations are confirmed for the destination market and intended workflow.

What information is needed for an accurate quotation?

Please share the destination country, intended clinical use, expected quantity, preferred configuration, local power standard and any required regulatory or tender documents. This lets ENOCHTEC prepare the most relevant technical and commercial proposal.

Yes. Available accessories, interface options, language, power standard, documentation and room integration can be reviewed for the destination market. Any change remains subject to the selected model, order quantity and regulatory requirements.

ENOCHTEC can support model selection, portfolio planning, technical documentation, product positioning and after-sales coordination for distributor and project orders. Training scope and service arrangements are confirmed according to the product and market.