Complete Ophthalmic & Optometry Solutions

Tel / WhatsApp  +86 186 1198 1496

KJ6B rechargeable streak retinoscope with charging base
ENOCHTEC · PROFESSIONAL EYE-CARE EQUIPMENT

KJ6 Series Streak Retinoscope

Model

KJ6 Series

KJ6 Series streak retinoscope with KJ6A AC-powered and KJ6B rechargeable configurations, a 1 m working distance, 3–20 mm adjustable streak and 360-degree streak rotation.

Need help selecting a configuration?
Tell us your market, clinical workflow and project requirements.

Product Highlights

Key Features

1 m working distance. Adjustable 3–20 mm streak. 360-degree streak rotation. Glass optical elements. KJ6A AC-powered model. KJ6B lithium-ion rechargeable model with at least 2 hours of documented continuous operation after a full charge.
Clinical Use

Applications

Objective refraction support and observation of refraction deflection and astigmatism axis during professional eye examinations.

KJ6 Streak Retinoscope Options

The KJ6 streak retinoscope series provides hand-held illumination for objective-refraction work and observation of refraction deflection and astigmatism axis. The supplied brochure documents two configurations: the KJ6A AC-powered retinoscope and the KJ6B rechargeable retinoscope.

Optical and Streak Controls

Both KJ6 models have a 1 m working distance, a 3–20 mm adjustable streak and 360-degree streak rotation. The brochure also describes glass optical elements. KJ6A uses a 3 V / 2.1 W halogen bulb, while KJ6B uses a 3.6 V / 2.7 W halogen bulb.

AC-powered or Rechargeable Configuration

KJ6A is the documented AC-powered option, with supply values of AC 220 V ±10%, 50 Hz ±10%, or AC 110 V ±10%, 60 Hz ±10%. KJ6B is the lithium-ion rechargeable option and has at least 2 hours of documented continuous operation after a full charge. The exact KJ6B charger, plug, charging time and battery capacity should be confirmed before quotation.

Selecting a KJ6 Retinoscope

Select KJ6A where a fixed AC-powered configuration is preferred, or KJ6B where rechargeable hand-held operation is required. Confirm the destination-market electrical configuration and whether a spare bulb, charger or carrying case is included in the final supply scope.

KJ6 Frequently Asked Questions

What is the documented working distance?

Both KJ6A and KJ6B have a documented working distance of 1 m.

How long can KJ6B operate after charging?

The brochure states at least 2 hours of continuous operation after a full charge. It does not state the charging time or battery capacity.

Are a carrying case and spare bulb included?

The brochure does not provide a definitive standard packing list. Confirm all supplied accessories in the approved quotation.

Review more optometry and refraction equipment, or contact ENOCHTEC to confirm the required KJ6 configuration and supply scope.

Project Fit

Configurations & Options

Choose KJ6A for the documented AC-powered configuration or KJ6B for the lithium-ion rechargeable configuration. Confirm charging input, destination-market plug, supplied bulb, carrying case and other accessories in the approved quotation.

Final configurations, accessories and documentation are confirmed according to market and project requirements.

Technical Specifications

Specification KJ6A KJ6B
Configuration AC-powered streak retinoscope Lithium-ion rechargeable streak retinoscope
Illumination bulb 3 V / 2.1 W halogen bulb 3.6 V / 2.7 W halogen bulb
Working distance 1 m 1 m
Adjustable streak 3–20 mm 3–20 mm
Streak rotation 360 degrees 360 degrees
Documented electrical / charging input AC 220 V ±10%, 50 Hz ±10%; or AC 110 V ±10%, 60 Hz ±10% The brochure repeats the same AC values in its table; treat them only as electrical or charging-input documentation until the exact charger is confirmed
Continuous operation Not separately stated At least 2 hours after a full charge

Discuss This Product with ENOCHTEC

Request specifications, configuration guidance or a distributor quotation for your market.

Product Questions & Buying Guidance

Practical answers for clinics, hospitals, distributors and project buyers evaluating this product. Final configurations are confirmed for the destination market and intended workflow.

What information is needed for an accurate quotation?

Please share the destination country, intended clinical use, expected quantity, preferred configuration, local power standard and any required regulatory or tender documents. This lets ENOCHTEC prepare the most relevant technical and commercial proposal.

Yes. Available accessories, interface options, language, power standard, documentation and room integration can be reviewed for the destination market. Any change remains subject to the selected model, order quantity and regulatory requirements.

ENOCHTEC can support model selection, portfolio planning, technical documentation, product positioning and after-sales coordination for distributor and project orders. Training scope and service arrangements are confirmed according to the product and market.