A-Scan vs B-Scan Ultrasound: What Each Shows and Which System Your Clinic Needs

Updated November 2026 · ENOCHTEC product team

An A-scan and a B-scan are two display modes of ophthalmic ultrasound. The A-scan sends a single beam along the axis of the eye and shows the echoes as spikes on a line, so it is used to measure distances such as axial length for intraocular lens (IOL) calculation. The B-scan sweeps the beam across the eye and builds a two-dimensional cross-section, so it is used to see the vitreous, retina and back of the eye, especially when a cataract, corneal opacity or bleeding hides them from view. In short: the A-scan measures, the B-scan visualizes.

Why ophthalmic ultrasound is still needed

Most eye examinations use light: the slit lamp, the ophthalmoscope, the fundus camera, OCT and optical biometry. Light needs a clear path. When the cornea is scarred, the lens has a dense cataract or the vitreous is filled with blood, light-based instruments cannot see or measure behind the opacity. Sound waves pass through these media, so ultrasound can still measure the length of the eye and show the posterior segment. That is why ultrasound remains part of cataract and retina services even in clinics that have optical biometry and OCT.

What an A-scan shows and when it is used

A-scan stands for amplitude mode. The probe sends one beam along the visual axis, and each surface it meets, such as the cornea, the front and back of the lens and the retina, returns an echo that appears as a spike on a one-dimensional trace. The distances between the spikes give anterior chamber depth, lens thickness, vitreous length and axial length.

Its main use is biometry before cataract surgery. Axial length, together with keratometry readings, goes into an IOL formula such as SRK-T, Holladay, Hoffer-Q or Haigis to calculate the lens power. A-scan biometry is especially important for eyes that an optical biometer cannot measure because the cataract is too dense.

There are two ways to couple the probe to the eye:

  • Contact A-scan: the probe touches the anesthetized cornea. It is quick, but pressing on the cornea indents it and can make the measured axial length too short, so gentle and consistent probe placement matters.
  • Immersion A-scan: a fluid-filled shell sits between the probe and the eye, so the cornea is not compressed. It takes a little longer to set up and is often preferred when accuracy is critical.

For a full comparison with non-contact optical biometry, see Optical Biometer vs A-Scan Ultrasound.

What a B-scan shows and when it is used

B-scan stands for brightness mode. The probe sweeps its beam across the eye, and the strength of each echo is shown as brightness at the matching point of a two-dimensional image. The result is a cross-sectional picture of the vitreous cavity, retina, choroid and posterior eye wall, which can be viewed live, frozen and reviewed. The examination is usually done with coupling gel, often through the closed eyelid.

A B-scan is most useful when the back of the eye cannot be seen directly, for example through a dense cataract, a corneal opacity or a vitreous hemorrhage. Typical questions it helps the clinician answer are:

  • Is the retina attached, or is there a retinal or choroidal detachment?
  • Are there vitreous opacities, membranes or a posterior vitreous detachment?
  • After trauma, is an intraocular foreign body suspected?
  • Is there a mass or another change in the posterior eye wall?

A B-scan can also be used before cataract surgery to check the posterior segment when the fundus cannot be seen, so that the surgeon knows what lies behind the cataract.

A-scan vs B-scan at a glance

Swipe sideways to see all columns →

A-scan (amplitude mode)B-scan (brightness mode)
DisplayOne-dimensional trace of echo spikesTwo-dimensional cross-sectional image
Main purposeMeasure: axial length, ACD, lens thicknessVisualize: vitreous, retina, posterior eye wall
Typical useBiometry and IOL calculation before cataract surgeryPosterior-segment assessment through opaque media
Probe couplingContact on the anesthetized cornea, or immersion shellCoupling gel, eyecup or water bath; often through the closed eyelid
ResultNumbers that feed an IOL formulaImages that are interpreted by a clinician
LimitationDoes not show an image of the eyeNot used to measure axial length for IOL power

Probe frequency and resolution

Ophthalmic A-scan and B-scan probes commonly work at about 10 MHz. Higher frequencies give finer detail but do not penetrate as deep, so the frequency is matched to the job. The Enochview-1000 uses 10 MHz for both its A-scan and B-scan, with a B-scan probing depth of at least 50 mm, axial resolution of 0.2 mm or better and lateral resolution of 0.3 mm or better. Ultrasonic pachymetry, which measures the thin cornea, uses a higher-frequency probe: 15–20 MHz on the MD-1000P.

Ultrasound images are much coarser than OCT images of the retinal layers. The two answer different questions: OCT gives micrometer-level detail but needs clear media, while a B-scan gives lower-resolution images that can be obtained through opaque media. See also OCT vs Fundus Camera.

Where corneal pachymetry fits

An ultrasonic pachymeter uses the same A-mode principle with a high-frequency probe to measure central corneal thickness. Corneal thickness is checked before corneal refractive surgery and helps interpret intraocular pressure readings, because thinner or thicker corneas can make measured IOP read lower or higher. Pachymetry is often combined with A-scan biometry in one portable unit. For ultrasound vs optical pachymetry and what to check before buying, see our pachymeter guide.

Which system does a clinic need?

  • Cataract service with an optical biometer: an A-scan for eyes the optical biometer cannot measure. A combined A/B scanner adds posterior-segment imaging when the fundus is hidden.
  • Cataract service without an optical biometer: an A-scan biometer with IOL formulas is the core instrument; add pachymetry if you also screen for refractive surgery.
  • Retina or general ophthalmology clinic: a B-scan for vitreous hemorrhage, suspected detachment and trauma cases, usually as part of a combined A/B system.
  • Outreach and mobile programmes: a portable A-scan biometer and pachymeter that runs on 100–240 V and can be carried between sites.

ENOCHTEC ophthalmic ultrasound

Swipe sideways to see all columns →

Enochview-1000MD-1000A/P
TypeA/B ultrasound workstationPortable A-scan biometer and pachymeter
A-scan10 MHz contact; 5–40 mm range; error ≤ ±0.05 mm; 10 readings averaged per group10 MHz contact or immersion (shell optional); 15–40 mm range; accuracy ±0.05 mm
B-scan10 MHz; depth ≥50 mm; up to 100-frame review; distance, area and annotation tools—
Pachymetry—15–20 MHz; 230–1200 μm; ±5 μm (P and A/P models)
IOL formulasSRK-T, SRK II, Holladay, Binkhorst-II, Hoffer-Q, HaigisSame six formulas plus five post-refractive methods
Display and format12.1-inch color touchscreen; 10 kgColor touch screen, footswitch, built-in printer; 1.7 kg
Choose it forCataract biometry plus posterior-segment imagingDedicated, portable biometry and corneal thickness

Specifications are for reference. The exact configuration, probes, accessories and documentation for your market are confirmed in your quotation.

For non-contact biometry in eyes with clear media, see the AL-VIEW Lite optical biometer. Compare every model in the ophthalmic ultrasound guide, or plan a complete ophthalmology clinic.

Frequently asked questions

What is the difference between an A-scan and a B-scan?

An A-scan is a one-dimensional trace used to measure distances in the eye, mainly axial length for IOL calculation. A B-scan is a two-dimensional cross-sectional image used to examine the vitreous, retina and posterior eye wall, especially when they cannot be seen directly.

Can a B-scan measure axial length for IOL calculation?

Distances can be marked on a B-scan image, but axial length for IOL power is measured with an A-scan or an optical biometer, which are designed for that precision.

Is contact or immersion A-scan more accurate?

Immersion A-scan avoids pressing on the cornea, which can shorten the measured axial length in contact A-scan. Contact A-scan is quicker; with gentle, consistent probe placement it is widely used. The MD-1000 supports both modes.

When is a B-scan used instead of OCT?

OCT needs clear media. When a dense cataract, corneal opacity or vitreous hemorrhage blocks the view, a B-scan can still image the posterior segment, although at lower resolution.

Does one machine do both A-scan and B-scan?

Yes. A combined A/B scanner such as the Enochview-1000 provides contact A-scan biometry with IOL formulas and 10 MHz B-scan imaging at one workstation.

Planning ultrasound for your clinic?

Tell us whether you need biometry, posterior-segment imaging, corneal thickness or all three, and whether the unit stays in one room or travels. We will recommend an A-scan, a combined A/B scanner or a portable biometer and pachymeter, and send a quotation.

Request a quote

This guide is general information for equipment buyers. Ultrasound examinations, IOL calculation and diagnosis are performed and interpreted by qualified eye-care professionals.