OCT vs Fundus Camera: What Each Shows and Which Your Clinic Needs First

Updated November 2026 · ENOCHTEC product team

A fundus camera takes a color photograph of the retina’s surface: optic disc, macula and blood vessels, as the clinician would see them through an ophthalmoscope. An OCT (optical coherence tomography) scanner produces cross-sectional images through the retinal layers and measures their thickness. The two answer different questions and are often used together. A fundus camera is usually the first purchase for screening and documentation; OCT is added when a clinic needs to examine and follow up the macula, retinal layers and optic nerve in depth.

What a fundus camera shows

A fundus camera photographs the back of the eye through the pupil in one flash, typically with a 50° field. The color image documents the optic disc, macula, retinal vessels and visible changes on the retinal surface, and it can be stored, compared between visits or sent for review. Non-mydriatic models can capture through an undilated pupil, which makes them practical for screening. Handheld models take the camera to the patient.

For the difference between mydriatic and non-mydriatic models, see our fundus camera guide.

What OCT shows

OCT scans the retina with near-infrared light and builds cross-sectional images from the reflections, a little like an ultrasound B-scan but with micrometer resolution. It shows the individual retinal layers, so changes beneath the surface that a photograph cannot show become visible, and it measures layer thickness. Software adds analyses such as macular thickness maps, retinal nerve fiber layer (RNFL) and optic-disc analysis, and progression over follow-up visits.

OCT vs fundus camera at a glance

Swipe sideways to see all columns →

Fundus cameraOCT
ImageColor photograph of the retinal surfaceCross-sections through the retinal layers
MeasurementsMainly visual documentation; some software adds area or cup-to-disc toolsLayer thickness, macular maps, RNFL and optic-disc analysis
Field of viewWide: typically 50° per image, larger with mosaicsFocused scan area, e.g. 6–12 mm
PupilNon-mydriatic models work through an undilated pupilNeeds a minimum pupil diameter (e.g. ≥3 mm)
FormatTabletop, portable or handheldTabletop
Typical useScreening, documentation, referral, telemedicineMacular and optic-nerve examination and follow-up

Which to buy first

  • Optometry practice or screening programme: a non-mydriatic fundus camera first, for documentation and referral.
  • Outreach or bedside work: a portable or handheld fundus camera.
  • Ophthalmology clinic with retina or glaucoma follow-up: OCT alongside a fundus camera, because the clinician usually needs both the surface photograph and the cross-section.
  • Hospital department: both, with DICOM connection to the hospital PACS where needed.

The OCT-500 shows an OCT en-face image rather than a color fundus photograph, so clinics that need color documentation pair it with a fundus camera.

ENOCHTEC OCT and fundus cameras

Swipe sideways to see all columns →

OCT-500RetiCam 3100Kestrel 3100mCFC-X
TypeSpectral-domain OCTNon-mydriatic fundus cameraNon-mydriatic automatic fundus cameraHandheld non-mydriatic fundus camera
ImageRetinal cross-sections; OCT en face50° color image; mosaic up to 135°50° color image; mosaic up to 135°50° color image
Key analysisUp to 7 retinal layers; macular, RNFL, optic disc, progressLesion-area and cup-to-disc tools (confirm scope)Confirmed with quotationConfirmed with quotation
Minimum pupil≥3 mm≥3.3 mm≥2.8 mm2.5 mm
Other modes—Anterior segment; FFA and FAF versionsRed-free, FFA, FAF (upgraded configuration)—
FormatTabletop, 13.3-inch touch screenTabletop, built-in computerTabletop, all-in-oneHandheld, under 600 g
ConnectivityConfirmed with quotationDICOM 3.0, PACS, LAN, USB, FTPDICOM 3.0, LAN, USB, FTPUSB 3.0, Wi-Fi, Bluetooth, SD card

Specifications are for reference. The exact configuration, accessories and documentation for your market are confirmed in your quotation.

Also available: the Kestrel 300 portable automatic fundus camera. Compare models in the OCT guide and the fundus imaging guide, or plan a complete ophthalmology clinic.

Related guide: Direct vs Indirect Ophthalmoscope vs Handheld Fundus Camera. Compares ophthalmoscopes with handheld fundus cameras for bedside work and screening.

Frequently asked questions

Can OCT replace a fundus camera?

Not usually. OCT shows cross-sections and layer thickness, while a fundus camera documents the whole visible retinal surface in color. Many clinics use both, and the OCT-500 shows an OCT en-face image rather than a color fundus photograph.

Do I need to dilate the pupil for OCT or fundus photography?

Non-mydriatic fundus cameras are designed to capture through an undilated pupil above a minimum size. OCT also needs a minimum pupil diameter; the OCT-500 lists ≥3 mm. Whether to dilate is the clinician’s decision.

Is a handheld fundus camera good enough for screening?

Handheld cameras such as the CFC-X take a 50° image and are used where a tabletop camera is impractical, such as outreach, bedside or home visits. Tabletop cameras offer more automation and options such as mosaics or angiography versions.

What does OCT measure?

OCT measures the thickness of the retina and its layers. Software such as that of the OCT-500 provides macular analysis, RNFL and optic-disc analysis, and progress analysis for follow-up.

Which should a new clinic buy first?

Most optometry practices and screening programmes start with a non-mydriatic fundus camera. Ophthalmology clinics that follow up macular or glaucoma patients usually add OCT.

Planning retinal imaging for your clinic?

Tell us who you examine, whether you screen, refer or follow up, and whether you need DICOM or PACS connection. We will recommend a fundus camera, OCT or both, and send a quotation.

Request a quote

This guide is general information for equipment buyers. Image interpretation and clinical decisions are made by qualified eye-care professionals.

© 2026 Beijing Enoch Corporation. All rights reserved. No part of this guide may be reproduced without prior written permission. Brief quotations with a link to the source are welcome.