A retinoscope is a handheld instrument for objective refraction: the examiner sweeps a beam of light across the pupil, watches how the reflex moves, and adds lenses until the movement stops. A streak retinoscope projects a line of light that can be rotated to find the astigmatism axis, and it is the preferred type today. A spot retinoscope projects a round spot and is less common. Retinoscopy needs no answers from the patient, which is why it stays useful for infants, young children and patients who cannot cooperate with subjective testing. It also needs a trained examiner and a way to place trial lenses, such as a trial lens set with a trial frame or a phoropter. For most clinics, a streak retinoscope is the one to buy.
Short answer: which one do you need?
- Optometry practices, eye clinics, teaching and outreach: a streak retinoscope such as the KJ6.
- Patients who cannot give reliable answers (infants, young children, developmental delay): retinoscopy gives an objective result without subjective responses.
- Fast automatic readings in the refraction room: an auto refractor, used alongside retinoscopy rather than instead of it.
- Placing the lenses: a trial lens set with a trial frame, or a phoropter (see our guide to manual vs automatic phoropters).
How does retinoscopy work?
The examiner looks along the light beam through the sight hole, sweeps the beam across the patient’s pupil and watches the red reflex. The direction in which the reflex moves shows where the eye’s far point lies. With motion (the reflex moves with the light) means the far point is behind the retinoscope, as in uncorrected hyperopia. Against motion means it lies between the retinoscope and the eye, as in uncorrected myopia (EyeWiki (American Academy of Ophthalmology)). The examiner adds plus lenses for with motion and minus lenses for against motion until the reflex shows no movement; this is neutralization. If the motion reverses, too much power has been added (EyeWiki (American Academy of Ophthalmology)).
With a streak, the examiner scans one meridian at a time and rotates the streak to find the axis. A vertical streak scans the horizontal meridian, and a horizontal streak scans the vertical meridian. The axis found by retinoscopy is usually only an estimate, and it is refined later during subjective refraction (StatPearls: Retinoscopy).
Working distance and the working-distance correction
The examiner sits at a set distance from the patient, so the result includes extra plus power that has to be removed. The correction is the inverse of the working distance in meters. At 50 cm, 1 ÷ 0.5 m = 2.00 D is subtracted from the retinoscopy result (EyeWiki (American Academy of Ophthalmology)). The KJ6 lists a working distance of 1 m; by the same arithmetic that is 1.00 D. Confirm the distance your examiners actually use before the correction is applied.
Streak retinoscope vs spot retinoscope vs auto refractor at a glance
Swipe sideways to see all columns →
| Streak retinoscope | Spot retinoscope | Auto refractor | |
|---|---|---|---|
| Light | Line of light that can be rotated | Round spot of light | Automatic measurement; no hand-held light to sweep |
| Astigmatism | Line reflex shows the meridians and the axis | Early electric spot models could not assess the two principal meridians | Cylinder and axis are reported by the instrument |
| Use today | Preferred type | Still in use, but less common | Common in the refraction room |
| Patient answers | Not needed | Not needed | Not needed, but the patient has to be positioned and fixate on a target |
| Examiner skill | Needs training and practice | Needs training and practice | Less hands-on skill for the reading itself |
| Lenses needed | Yes: trial lenses, trial frame or phoropter | Yes: trial lenses, trial frame or phoropter | No for the measurement |
Based on EyeWiki (American Academy of Ophthalmology) and StatPearls: Retinoscopy. Check each instrument’s own documentation for what it measures.
When is retinoscopy the right tool?
- Infants, young children and patients with developmental delay. Retinoscopy needs no subjective answers, so it can set a refractive endpoint when other methods are not possible (EyeWiki (American Academy of Ophthalmology); StatPearls: Retinoscopy).
- Cycloplegic refraction. Wet retinoscopy is used for uncooperative children and for amblyopia, strabismus, accommodative spasm, latent hyperopia, high anisometropia and other pediatric refractive problems (StatPearls: Retinoscopy).
- Clues about the cornea and media. An irregular reflex, such as a scissor-like movement of the streak, can point to irregular astigmatism, and retinoscopy can help assess cataract and other media problems (StatPearls: Retinoscopy; EyeWiki (American Academy of Ophthalmology)).
- Accommodation. Dynamic retinoscopy is used to look at accommodative function (EyeWiki (American Academy of Ophthalmology)).
Retinoscopy is a skill that takes practice. Accuracy depends on the examiner’s technique, on a steady vertex distance, and on the patient’s attention and eye movements (StatPearls: Retinoscopy). Cycloplegic drops can cause temporary blurred vision and light sensitivity.
What do you need besides the retinoscope?
A retinoscope only gives the examiner an objective reading. To neutralize the reflex you need lenses: a trial lens set with a trial frame, or a phoropter. A fixation target, a room that can be darkened and, for routine work, an auto refractor complete the set. Our guide to auto refractor vs auto refractor keratometer explains when each is needed, and a complete refraction room can combine them.
ENOCHTEC KJ6 streak retinoscope
ENOCHTEC’s retinoscope range is the KJ6 streak series; we do not list spot retinoscopes. Both models share the same optics and streak controls and differ in power supply.
Swipe sideways to see all columns →
| KJ6A | KJ6B | |
|---|---|---|
| Configuration | AC-powered | Lithium-ion rechargeable |
| Bulb | 3 V / 2.1 W halogen | 3.6 V / 2.7 W halogen |
| Working distance | 1 m | 1 m |
| Adjustable streak | 3–20 mm | 3–20 mm |
| Streak rotation | 360° | 360° |
| Optical elements | Glass | Glass |
| Power | AC 220 V ±10%, 50 Hz or AC 110 V ±10%, 60 Hz | At least 2 hours of continuous operation after a full charge |
| Suits | Fixed AC-powered use | Rechargeable hand-held use |
Specifications are for reference. Confirm the KJ6B charger, plug, charging time and battery capacity, and whether a spare bulb, charger or carrying case is included, in the quotation.
What to check before buying
- Streak type and controls. A streak retinoscope with an adjustable streak and 360° rotation, so the examiner can find the axis in any meridian.
- Optics. Ask whether the optical elements are glass and how the unit is protected against misalignment.
- Bulb. Check the bulb type and whether spare bulbs are supplied.
- Power. Choose AC or rechargeable according to where it will be used, and confirm the plug and charger for your market.
- Working distance. Confirm the working distance the instrument is designed for and the one your examiners will use.
- Lenses and training. Plan the trial lenses or phoropter, and who will perform and interpret retinoscopy.
- Documents for your market. Confirm registration and documentation requirements before quotation.
Sources: EyeWiki (American Academy of Ophthalmology); StatPearls: Retinoscopy; and the KJ6 product page.
Frequently asked questions
What is the difference between a streak and a spot retinoscope?
A streak retinoscope projects a line of light that can be rotated, which makes the astigmatism axis easier to judge. A spot retinoscope projects a round spot of light; spot models are still in use but are less common, and early electric spot models could not assess the two principal meridians as well.
What do “with” and “against” motion mean?
They describe how the pupil reflex moves compared with the light. With motion means the reflex moves in the same direction as the light and calls for added plus power; against motion means it moves the opposite way and calls for added minus power. The examiner adds lenses until the reflex no longer moves, which is called neutralization.
How is the working distance handled?
The retinoscopy result is reduced by the dioptric equivalent of the working distance, which is 1 divided by the distance in meters. At 50 cm that is 2.00 D. The KJ6 lists a working distance of 1 m, so confirm the distance your examiners will use before applying the correction.
Can a retinoscope replace an auto refractor?
They do different jobs. An auto refractor gives an automatic objective reading in the refraction room. A retinoscope needs a trained examiner and trial lenses, but it requires no answers from the patient, so it remains useful for infants, young children and patients who cannot cooperate with subjective testing.
Is cycloplegia always needed for retinoscopy?
No. Non-cycloplegic (dry) retinoscopy leaves accommodation active, while cycloplegic (wet) retinoscopy uses drops to relax it and is especially useful for uncooperative children and for conditions such as latent hyperopia or accommodative spasm. The drops can cause temporary blurred vision and light sensitivity.
Which KJ6 model should I choose?
Choose the KJ6A where an AC-powered configuration is preferred, or the KJ6B where rechargeable hand-held operation is required. The KJ6B runs for at least 2 hours of continuous operation after a full charge. Charger, plug, bulb and case are confirmed in the quotation.