Visual Field Analyzer (Perimeter) Guide: Projection vs Hidden LED

Updated November 2026 · ENOCHTEC product team

A visual field analyzer (also called a perimeter) measures how far and how sensitively a patient sees across the visual field. The patient looks at a fixed point and presses a button each time a light stimulus appears. It is used mainly to diagnose and follow glaucoma, and also in macular and neurological disease. Today’s automated perimeters generate the stimulus in two ways: by projection, where one light source projects each stimulus onto the bowl, or with an array of hidden LEDs at fixed positions. Both run standard white-on-white perimetry; the difference lies in how the stimulus is produced and in the extra tests a model offers, such as blue-yellow (SWAP) and kinetic perimetry.

Short answer: which perimeter does your site need?

  • Optical practice or optometry clinic with glaucoma screening: a static perimeter with 24-2 and 30-2 programs, screening tests and clear reports for referral.
  • Eye clinic with a glaucoma service: an analyzer with a fast threshold strategy, fixation control, progression analysis and a network connection.
  • Hospital and neurology service: a projection perimeter with kinetic testing for the peripheral field, and DICOM to feed the patient record.

What does a visual field test measure?

Automated static perimetry presents stimuli of different intensities at fixed points and finds, at each point, the dimmest stimulus the patient sees. This is the threshold, expressed in decibels (dB). The result is compared with age-matched normal values and summarized in indices such as mean deviation (MD), pattern standard deviation (PSD), the visual field index (VFI) and the glaucoma hemifield test (GHT). Reliability is judged from fixation losses, false positives and false negatives (StatPearls: Humphrey Visual Field).

The most used patterns are the 30-2 (76 points over the central 30°), the 24-2 (54 points) and the 10-2 (68 points over the central 10°, for central and macular defects). Screening tests are faster and only record whether each point is seen. Kinetic perimetry instead moves a stimulus of fixed intensity along an arc to map the edges of the field, which suits the peripheral field and neurological work (StatPearls: Humphrey Visual Field).

Projection or hidden LED: how the stimulus is generated

In a projection perimeter, a single light source and an optical system project each stimulus onto the diffusing surface of the bowl. Because every stimulus comes from the same source, its intensity is the same at any location, and its position can change freely, which also allows kinetic tests.

In a hidden LED perimeter, hundreds of LEDs behind the bowl at fixed positions act as the stimulus points. The build is robust and compact, but the test positions are set by the array, and intensity at each point depends on its own LED and its calibration.

Swipe sideways to see all columns →

Projection perimeterHidden LED perimeter
Stimulus generationOne light source projects each stimulus onto the bowlFixed LEDs behind the bowl, one per point
Intensity between pointsSame at every point, from one sourceDepends on each LED and its calibration
Test positionsFree; allows custom programs and kinetic testingFixed by the LED array
Standard 24-2 / 30-2 testingYesYes
Kinetic perimetryPossible on models that include itNot usual

What to compare when choosing a perimeter

  1. Stimulus and background: the white size III stimulus on a dim background, with a 0–50 dB intensity range (the ENOCHTEC IFA and IVS list 31.5 asb, or 10 cd/m²).
  2. Programs and strategies: 30-2, 24-2, 10-2, macula, screening and fast threshold strategies that shorten the test.
  3. Fixation control: gaze tracking, blink control and blind-spot monitoring make results more reliable, especially in older patients.
  4. Analysis: VFI, MD, PSD and GHT, glaucoma progression analysis and report formats your clinicians already know.
  5. Additional tests: blue-yellow (SWAP) and kinetic perimetry, if you need them.
  6. Connectivity: network, printer and, in hospitals, DICOM with Worklist and report export to PACS.
  7. Space and environment: the test runs in a room with controlled light, with the patient seated at the bowl for several minutes per eye, so plan the correction lenses, chin rest and a quiet room.

ENOCHTEC visual field analyzers

Swipe sideways to see all columns →

IFA-900 / 950 / 960IVS-201A / 201BBIO-1000 Plus
TypeFront-projection perimeterHidden LED perimeterAutomatic static perimeter
Test distance30 cm30 cm300 mm bowl radius
Stimulus and backgroundGoldmann III (I–V on IFA-950/960), 0.08–10,000 asb (0–50 dB); background 31.5 asb (10 cd/m²)Goldmann III, 0.08–10,000 asb (0–50 dB); background 31.5 asb (10 cd/m²)White background, 10 cd/m²
Temporal range90°90°70°
ProgramsT30-2, T24-2, T10-2, macula, T60-4, T60-2, screeningT30-2, T24-2, T10-2, macula, T60-4, T60-2, screening30-2, 24-2, 10-2, macula, Nasal Ladder and user-defined programs
Blue-yellow (SWAP)IFA-950 and IFA-960IVS-201A—
Kinetic perimetryIFA-960——
Fixation monitoringGaze tracking, blink control, blind-spot monitor, pupil measurementGaze tracking, blink control, blind-spot monitor, pupil measurementFalse positive, false negative and fixation loss indicators; adjustable chin rest
ConnectivityEthernet, WiFi; optional DICOMEthernet, WiFi; optional DICOMRJ45 Ethernet and four USB 2.0

Specifications are for reference. The exact configuration, accessories and documentation for your market are confirmed in the quotation. The IFA and IVS use the HISA threshold strategy, which adapts the test to the patient’s responses to shorten it, and report VFI, GHT and glaucoma progression analysis. Compare all models in our visual field analyzer and perimetry buying guide, or see how a perimeter fits a complete ophthalmology clinic. For the other half of a glaucoma workup, read our guide to non-contact vs rebound tonometers.

Sources: StatPearls: Humphrey Visual Field (Ruia and Tripathy, StatPearls Publishing); IFA-900 / 950 / 960, IVS-201A / 201B and BIO-1000 Plus product pages.

Frequently asked questions

Is a perimeter the same as a visual field analyzer?

Yes. Perimeter, perimetry unit, computerized perimeter and visual field analyzer all describe the instrument that measures the visual field. In some markets it is also called a campimeter.

What do 24-2, 30-2 and 10-2 mean?

They are test patterns for static threshold perimetry. The 30-2 tests 76 points covering the central 30°, the 24-2 tests 54 points in the central 24°, and the 10-2 tests 68 points in the central 10°, which makes it suited to central and macular defects (StatPearls: Humphrey Visual Field).

Is a projection or a hidden LED perimeter better?

Both run standard white-on-white threshold testing. A projection perimeter delivers every stimulus from the same light source and allows free stimulus positions and kinetic testing; a hidden LED perimeter uses fixed positions in a compact build. The better choice depends on the tests you need.

What is blue-yellow (SWAP) perimetry?

It tests with a blue stimulus on a bright yellow background. It is offered as an additional test; the literature describes its clinical role as debated, so it is used alongside standard white-on-white testing and not instead of it.

Does refractive error affect a visual field test?

Yes. Uncorrected refractive error can lower sensitivity across the whole field, and patients such as older adults or pseudophakic patients may need a near addition for the test distance. Pupil size and fatigue also matter (StatPearls: Humphrey Visual Field).

Which ENOCHTEC perimeter offers kinetic testing?

Kinetic testing is available on the IFA-960. The IFA-900, IFA-950, IVS-201A/B and BIO-1000 Plus are static perimeters.

Looking for a perimeter for your site?

Tell us whether you will use it for screening or glaucoma follow-up, whether you need kinetic perimetry or SWAP, and how reports should reach your records. We will recommend a model and send a quotation.

Request a quote

This guide is general information for equipment buyers. Performing and interpreting visual field tests are the responsibility of qualified eye-care professionals.