BIO-1000 Plus automatic perimeter for visual field assessment
ENOCHTEC · PROFESSIONAL EYE-CARE EQUIPMENT

BIO-1000 Plus Automatic Perimeter

Model

BIO-1000 Plus

BIO-1000 Plus automatic static perimeter for professional visual-field assessment, with camera monitoring, central and peripheral test programs, patient records and report printing.

Need help selecting a configuration?
Tell us your market, clinical workflow and project requirements.

Product Highlights

Key Features

Static visual-field testing. 300 mm viewing distance and 10 cd/m² white background. Listed field extent of 45° nasal, 70° temporal, 45° superior and 60° inferior. Central 30-2, 24-2 and 10-2 programs plus Macular and Nasal Ladder programs. Threshold, screening and user-defined program functions. Camera monitoring, movable chin rest, patient response button, patient records and report printing. RJ45 Ethernet and four USB 2.0 interfaces.
Clinical Use

Applications

Professional static visual-field assessment, including workflows that support glaucoma evaluation. The system must be operated by trained personnel under the approved instructions for use; results require professional interpretation with the patient’s broader clinical information.

Static Visual-field Assessment

The BIO-1000 Plus automatic perimeter is a static visual-field system for trained eye-care professionals. It combines a hemispherical visual-field stimulator, camera monitoring, patient response control and computer-based operation for examination, record management and result review.

Central and Peripheral Test Coverage

The listed viewing distance is 300 mm, with a white background luminance of 10 cd/m². The stated minimum test-point extent is 45° nasal, 70° temporal, 45° superior and 60° inferior. The system provides at least 60 stimulus positions within 0°-25°, 30 positions beyond 25°-50° and 15 positions beyond 50°-70°, for a total of 105 minimum positions.

Programs and Result Review

Central programs include 30-2, 24-2 and 10-2. Macular and Nasal Ladder programs, threshold and screening strategies, and user-defined program creation are also described. Patient records can be created, saved, browsed and printed. Reliability information includes false-positive, false-negative and fixation-loss indicators, while summary indices include MS, MD, SF and PSD.

Positioning and Connectivity

A camera supports observation during testing. The listed chin-rest travel is 30 ± 5 mm horizontally and 40 ± 5 mm vertically. Four USB 2.0 interfaces support compatible keyboard, mouse or printer connections, and the system lists an RJ45 Ethernet interface. Any database transfer, network or institutional-system deployment must be confirmed for the selected installation.

BIO-1000 Plus Frequently Asked Questions

Which central programs are listed?

Available central programs include 30-2, 24-2 and 10-2. Macular and Nasal Ladder programs are also listed. Confirm the exact software build and available program set for the supplied unit.

What directional field extent is listed?

The listed minimum test-point eccentricities are 45° nasal, 70° temporal, 45° superior and 60° inferior.

Can the operator monitor patient positioning?

Yes. The system structure includes camera monitoring, and the chin rest provides horizontal and vertical adjustment.

Can records be printed or transferred?

Patient-record management and report printing are supported, with USB 2.0 and RJ45 interfaces listed. Confirm the printer, file workflow, network implementation and integration scope before deployment.

View the ophthalmic equipment range, or email ENOCHTEC sales with your market, quantity and visual-field workflow requirements.

Project Fit

Configurations & Options

The manual describes a visual-field stimulator with camera monitoring, computer system, patient response button and BIO software. Confirm the supplied computer/display, printer, corrective-lens accessories, software version and language, record/export functions, network implementation, installation, training, service and destination-market requirements in the approved quotation.

Final configurations, accessories and documentation are confirmed according to market and project requirements.

Technical Specifications

Specification BIO-1000 Plus
Instrument type Automatic static perimeter
Sphere radius / viewing distance 300 mm
Background White, 10 cd/m²
Minimum test-point eccentricity Nasal 45°; temporal 70°; superior 45°; inferior 60°
Minimum stimulus positions, 0°-25° 60
Minimum stimulus positions, greater than 25°-50° 30
Minimum stimulus positions, greater than 50°-70° 15
Total minimum stimulus positions 105
30-2 program 0°-30°; 76 points
24-2 program 0°-24°; 54 points
10-2 program 0°-10°; 68 points
Macular program 0°-5°; 16 points
Nasal Ladder program 30°-50°; 14 points
Strategies / programs Threshold, screening and user-defined program functions; exact software set subject to supplied version
Reliability indicators False positive, false negative and fixation loss
Summary indices MS, MD, SF and PSD
Chin-rest travel Horizontal 30 ± 5 mm; vertical 40 ± 5 mm
Network interface RJ45 Ethernet, IEEE 802.3; implementation scope requires confirmation
USB Four USB 2.0 interfaces; supports compatible keyboard, mouse or printer
User-interface languages Chinese and English selectable
Power supply 220 V, 50 Hz
Power input 200 VA
Operating environment +10 to +40 °C; 40%-80% RH; 620-1060 hPa
Storage environment -40 to +55 °C; up to 85% RH; 620-1060 hPa

Discuss This Product with ENOCHTEC

Request specifications, configuration guidance or a distributor quotation for your market.

Product Questions & Buying Guidance

Practical answers for clinics, hospitals, distributors and project buyers evaluating this product. Final configurations are confirmed for the destination market and intended workflow.

What information is needed for an accurate quotation?

Please share the destination country, intended clinical use, expected quantity, preferred configuration, local power standard and any required regulatory or tender documents. This lets ENOCHTEC prepare the most relevant technical and commercial proposal.

Yes. Available accessories, interface options, language, power standard, documentation and room integration can be reviewed for the destination market. Any change remains subject to the selected model, order quantity and regulatory requirements.

ENOCHTEC can support model selection, portfolio planning, technical documentation, product positioning and after-sales coordination for distributor and project orders. Training scope and service arrangements are confirmed according to the product and market.