Complete Ophthalmic & Optometry Solutions

Tel / WhatsApp  +86 186 1198 1496

ARK-710 auto refractor keratometer front three-quarter product view
ENOCHTEC · PROFESSIONAL EYE-CARE EQUIPMENT

ARK-710 Auto Refractor Keratometer

Model

ARK-710

The ARK-710 combines objective refraction and corneal-curvature measurement with K&R, REF and KRT modes, automatic eye tracking, a 360° rotatable 9-inch touch display, automatic printing and Bluetooth communication.

Need help selecting a configuration?
Tell us your market, clinical workflow and project requirements.

Product Highlights

Key Features

K&R, REF and KRT measurement modes; automatic eye tracking; 360° rotatable 9-inch touch display; automatic printing and paper cutting; Bluetooth communication.
Clinical Use

Applications

Objective refraction and corneal-curvature measurement in optometry clinics, ophthalmology practices, hospitals and optical centers. Results require professional interpretation.

Objective Refraction and Corneal Curvature in One Unit

The ARK-710 auto refractor keratometer combines objective refractive measurement and corneal-curvature measurement in a tabletop instrument. Its documented K&R, REF and KRT modes let the operator select a combined workflow or an individual measurement mode according to the examination sequence. Results are measurement outputs for professional review and should not be presented as a diagnosis or treatment recommendation.

Documented Measurement Modes

  • K&R mode: diopter and corneal-curvature measurement.
  • REF mode: diopter measurement.
  • KRT mode: corneal-curvature measurement.

The current ARK-710 brochure lists vertex-distance settings of 0, 12.0, 13.75 and 15.00 mm. The documented spherical range is -25.00 D to +25.00 D, the cylindrical range is -10.00 D to +10.00 D and the astigmatic-axis range is 0°–180°. PD is listed from 10 to 85 mm, with a minimum pupil diameter of 2.0 mm.

Corneal Measurement Scope

For the keratometry workflow, the brochure lists a corneal-curvature radius of 5–10 mm, a corneal astigmatic-axis range of 0°–180° and a corneal-diameter range of 2–12 mm. These ranges describe the documented instrument scope; they are not accuracy, repeatability or clinical-outcome claims.

Display, Alignment and Data Handling

Automatic eye tracking supports alignment during measurement. The 9-inch touch LCD can rotate through 360°, helping the operator position the control surface for different room layouts. The brochure also identifies Bluetooth communication, automatic printing and automatic paper cutting. Confirm the receiving-system requirements and permitted data workflow for the destination market before quotation.

Installation and Quotation Checks

The listed power requirement is AC 220 V, 50 Hz, 75 VA. The documented unit dimensions are 300(W) × 450(D) × 500–530(H) mm and the listed weight is 20 kg. Before ordering, confirm the destination electrical standard, included printer supplies, cables, accessories, language, workstation arrangement, documentation and service scope. Items not explicitly listed in the current brochure should be treated as quotation-dependent.

ARK-710 Frequently Asked Questions

Does ARK-710 measure both refraction and corneal curvature?

Yes. The brochure lists K&R for combined measurement, REF for diopter measurement and KRT for corneal-curvature measurement.

What display does it use?

The documented configuration uses a 9-inch touch LCD that can rotate through 360°.

Is ARK-710 a handheld autorefractor?

No. The supplied material presents it as a tabletop auto refractor keratometer.

Review more optometry and refraction equipment, or contact ENOCHTEC to confirm the ARK-710 configuration for your market.

Project Fit

Configurations & Options

Confirm the destination electrical standard, receiving-system requirements, included printer supplies, cables, accessories, language, workstation arrangement, documentation and service scope in the approved quotation.

Final configurations, accessories and documentation are confirmed according to market and project requirements.

Technical Specifications

Model ARK-710
Measurement modes K&R / REF / KRT
Vertex distance 0 / 12.0 / 13.75 / 15.00 mm
Spherical power -25.00 D to +25.00 D
Cylindrical power -10.00 D to +10.00 D
Astigmatic axis 0°–180°
PD 10–85 mm
Minimum pupil diameter 2.0 mm
Corneal-curvature radius 5–10 mm
Corneal astigmatic axis 0°–180°
Corneal diameter 2–12 mm
Display 9-inch touch LCD; 360° rotation
Alignment Automatic eye tracking
Output Automatic printing, automatic paper cutting, Bluetooth communication
Power AC 220 V / 50 Hz / 75 VA
Dimensions / weight 300(W) × 450(D) × 500–530(H) mm / 20 kg

Discuss This Product with ENOCHTEC

Request specifications, configuration guidance or a distributor quotation for your market.

Product Questions & Buying Guidance

Practical answers for clinics, hospitals, distributors and project buyers evaluating this product. Final configurations are confirmed for the destination market and intended workflow.

What information is needed for an accurate quotation?

Please share the destination country, intended clinical use, expected quantity, preferred configuration, local power standard and any required regulatory or tender documents. This lets ENOCHTEC prepare the most relevant technical and commercial proposal.

Yes. Available accessories, interface options, language, power standard, documentation and room integration can be reviewed for the destination market. Any change remains subject to the selected model, order quantity and regulatory requirements.

ENOCHTEC can support model selection, portfolio planning, technical documentation, product positioning and after-sales coordination for distributor and project orders. Training scope and service arrangements are confirmed according to the product and market.